4. Operation
Using the Setup Menu
rëÉê=mêÉÑÉêÉåÅÉ
From the Setup Menu, select User Preference to display the User Preference Menu:
US ER P RE FERENCE
> I n A u t o A c q u i r e
Figure 4-39. User Preference Menu (sample)
The following functions are available:
få=^ìíç=^ÅèìáêÉ
The In Auto Acquire function enables or disables the Input Auto Acquire mode, which
acquires a signal for the input. Values for In Auto Acquire are:
When In Auto Acquire is ON, and an input has a saved configuration file, the system
attempts to use the saved file. If the input timing matches the timing in the saved
configuration file, the saved file is used.
The system always performs a full sync (timing) acquisition on the selected input signal
under the following conditions:
When In Auto Acquire is ON, and the input source is non-digital, the system uses the
following library search order:
70
Aut o Inp ut Cfg.
Aut o Inp ut Save
B l a c k A u t o T a k e

Key Auto Take

M e n u C o n t e x t

In Auto Acquire

Auto Input Config

Auto Input Save

Auto Take

Black Auto Take

Key Auto Take

Menu Context

When an input without a saved configuration file is selected
When the input type is changed
When the input signal's sync rate is changed
When an input with a saved configuration file is selected, but the input timing is
different from the saved configuration
Saved configuration files defined in the File Association Menu for each input
channel
The user's library of saved files
The standard Input Format table defined in Appendix A, in the
section on page 122
A best guess
O N
O F F
O N
O F F
O F F
O F F
OFF
and
ON
"Format
DCS-200 • User's Guide
(default).
Table"