Icrst; Icsav; Icsp; Ihatv - Barco DCS-200 User Manual

Hide thumbs Also See for DCS-200:
Table of Contents

Advertisement

_K==oÉãçíÉ=`çåíêçä
Remote Commands
f`opq
f`p^s=
f`pm
fe^qs
140
1:"1"
2:"2"
.
.
64:"64"
Description: Reset Input Configuration to the input default values
Command Format: ICRST -i (input)
Parameters: -i (input): 1 - 9
Query Format: N/A
Query Response: N/A
Description: Saves Input Configuration. The input's IMAP is updated if the
-f (file) parameter is specified.
Command Format: ICSAV -i (input) -f (file)
Parameters: -i (input):1 - 9
-f (file): 1 - 64. If specified, update the File Association menu to reflect
the selected file number. If not specified, use the current file number
from the ICREC query.
Query Format: N/A
Query Response: N/A
Description: Input Colorspace Adjust
Command Format: ICSP -i (input) -c (color)
Parameters:
-i (input): 1 - 9
-c (color): 0-RGB, 1-SMPTE
Query Format: ICSP -i (input) -?
Query Response: ICSP -i (input) -c (color) --min 0 --max 1
List Format: Each input type will have a different list for colorspace.
ICSP -i (input) --list
Description: Input Horizontal Active Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
Command Format: IHATV -i (input) -a (active)
DCS-200 • User's Guide

Advertisement

Table of Contents
loading