Before Upgrade

Station Speed Dialing Change

Names assigned to station speed dial entries (configured in Extension
Configuration) are now stored in the local server instead of the client's
machine. When upgrading to 5.0 from 4.6, speed dial names configured for
4.6 clients (AltiServ/AltiView/AltiAgent users) are not carried over after
the upgrade.

VoIP Board Upgrade

When you upgrade to OE 5.0 from AltiWare OE 4.0, all 8-port VoIP boards
are automatically upgraded to 12-port boards. The 12-port board can be
configured to a 30-port board. The original ports retain their configurations,
but you must configure the new ports if you want to use them.

Shutting Down the AltiGen Switching Service

Before installing this upgrade on the AltiServ system, please make sure that
the AltiAdmin application and the AltiGen Switching Service are not
running.
You can shutdown the AltiGen Switching Service Com Server and the
AltiAdmin application at the same time by running AltiAdmin, logging in
and selecting Services
Note:
Stopping the AltiGen Switching Service COM Server will
automatically stop all the auxiliary services.
These are the Windows 2000 services distributed with AltiWare:
AltiGen Switching Service COM Server
AltiGen Messaging Service COM Server
AltiGen SMTP Service COM Server
AltiGen POP3 Service COM Server
AltiGen Exchange Integration Service COM Server
AltiGen Backup/Restore Service
AltiGen Keep Up Service
AltiGen Internal Logger Server
AltiGen External Features Server
3-20 AltiWare OE System Installation & Administration Manual
Shutdown Switching.