Setting up Extensions
To set the codec of an IP extension with static IP addressing:
1.
Select the extension in the Static IP Extensions list.
2.
In the drop-down below the list, select the codec to use for this
extension.
To set the codec for a connection to another AltiServ server:
1.
Select the server in the Servers list.
2.
In the drop-down below the list, select the codec to use for a
connection to this server.
Note:
AltiServ-to-AltiServ IP connections between systems using OE
4.6 must use the same codec.
To set ranges and values for dynamic IP addressing:
1.
In the G711 IP Ranges list, click the Add button. The Add IP Codec
Setting dialog appears.
Figure 5. Add IP Codec Setting
2.
In the Add IP Codec Setting dialog, specify Single or Range to set a
single dynamic IP address or a range of addresses.
3.
Enter a Start value and, for a Range, an End value for the dynamic IP
addresses your IP extension users can access.
You cannot use the minimum and maximum values (0.0.0.0. and
255.255.255.255).
4.
Click OK.
5.
Repeat these steps for every range or value you wish to make available
for users of IP extensions with dynamic addressing.
Setting Ranges and Values with the 30-Port IP Board
If you do not have 12-Port IP boards in your system, and only have a 30-
Port IP board, you must configure the system to use G.711 only.