Incomplete Array - Asus DS300i User Manual

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

Incomplete Array

An incomplete array can result from any of the following conditions:
The NVRAM watermark for the RAID level migration currently in progress is
missing or cannot be found
A physical drive goes missing during transport
See ―Physical Drive Failed‖ on page 388 for more information.
When ASUS Storage discovers an incomplete array, ASUS Storage
Management displays a dialog box asking you to:
Click the OK button to accept the incomplete array
Click the Cancel button to reject the incomplete array
Before you accept the incomplete array, be sure all of the physical drives are
present and that their drive carriers are properly installed into the enclosure. See
―Installing Disk Drives‖ on page 15.
If you choose to accept the incomplete array:
1.
Click OK in the incomplete array dialog box.
2.
Check the operational status of the logical drives in the array.
If the logical drives are critical or degraded, proceed with a rebuild.
See ―Rebuilding a Disk Array‖ on page 159 (ASUS Storage
Management) or page 231 (CLU).
If the logical drives are offline, contact Technical Support. See
page 402.
3.
Restore your data from a backup source, if required.
The CLU displays the option Accept Incomplete Array on the Disk Array Info and
Settings screen. Highlight the option and press Enter to accept the incomplete
array.
If you choose NOT to accept the incomplete array:
1.
Click Cancel in the incomplete array dialog box.
2.
Do one of the following:
Delete the array. See ―Deleting a Disk Array‖ on page 154 (ASUS
Storage Management) or page 229 (CLU).
Replace the missing physical drive.
387
Chapter 10: Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f

Table of Contents