Making UPS Settings
These settings control how the ASUS Storage subsystem detects the UPS unit
and responds to data reported by the UPS unit.
To make UPS settings:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight UPS Management and press Enter.
3.
Highlight UPS Settings and press Enter.
4.
Perform the following actions as required:
Verify the Current UPS Communication method. See Note 1 below.
Choose a Detection Setting from the dropdown menu:
Choose an Action Mode from the dropdown menu:
Type values into the Threshold fields. See Note 2 below.
For UPS units with network cards, type IP address or DNS name in the
field provided. See Note 3 below.
5.
Press Ctrl-A to save your settings.
Notes
1.
ASUS Storage supports multiple UPS units using network or serial
connections, but a combination of both methods.
SNMP – USB connection.
Serial – USB connection.
Unknown – No connection.
Automatic – Default. If a UPS is detected when the subsystem
boots, the setting changes to Enable.
Enable – Monitors UPS. Settings changes, reports warnings, and
logs events.
Disable – Monitors UPS only.
Shutdown – Shuts down the subsystem when a Threshold value is
exceeded.
None – No additional action when Threshold value is exceeded.
Running Time Remaining Threshold – Actual time below this
value resets adaptive writeback cache to writethrough.
Warning Temperature Threshold – Actual temperature above this
value triggers a warning and logs an event.
Battery Charge Remaining Threshold – Reserve capacity below
this percentage triggers a warning and logs an event.