Asus DS300i User Manual page 396

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

Reported Event
PDM is completed
PDM is paused
PDM is resumed
PDM is stopped
PDM is switched to
rebuild.
PDM is stopped internally The destination drive was removed or used for a
Physical Disk
Physical disk is marked
online
Physical disk is marked
online
Physical disk is marked
as dead.
Physical disk is marked
as dead after it was
removed and reinserted
by the user.
Physical disk has been
reset
Physical disk assigned as
global spare
Physical disk is no longer
assigned as global spare
Physical disk assigned as
dedicated spare
Physical disk is no longer
assigned as dedicated
spare
Physical disk has been
inserted
Normal.
PDM paused because of user intervention, schedule
or a higher priority background activity.
PDM has resumed again after a pause.
PDM stopped because of user intervention, schedule
or the logical drive was deleted or went critical or
offline.
PDM changed to rebuild because the logical drive
went critical
rebuild.
Disk drive restored to normal operation.
Disk drive removed from service due to errors. If
necessary, try to force the disk online. See page 143
(ASUS Storage Management) or page 224 (CLU).
Disk drive failure. Replace the disk drive.
Try forcing the disk online. See page 143 (ASUS
Storage Management) or page 224 (CLU)
Disk drive reset after error and should function
normally.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
A disk drive has been inserted into the ASUS Storage
subsystem.
377
Chapter 10: Troubleshooting
Corrective Action