Asus DS300i User Manual page 398

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

Reported Event
PSU is installed/
operational and turned on
PSU is installed/
operational and turned off
PSU is malfunctioning
and turned on/off
PSU 12V/5V/3.3V power
is out of the threshold
range
PSU 12V/5V/3.3V power
is within the range
RAID Level Migration
RAID Level migration is
started
RAID Level migration is
completed
RAID Level migration is
paused
RAID Level migration is
resumed
RAID Level migration is
stopped
RAID Level migration has
encountered a physical
disk error
RAID Level migration is
aborted due to an internal
error.
RAID Level migration is
queued
Migration has detected/
cleared stale NV
Watermark
Normal.
A power supply unit is present but turned off. Turn on
the power supply.
Replace the power supply unit.
Replace the power supply unit.
Normal.
Result of settings or user action. Normal.
Normal.
Migration paused because of user intervention,
schedule or a higher priority background activity.
Migration has resumed again after a pause.
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed.
System resources are low. Reduce system load or
restart the ASUS Storage. See page 130 (ASUS
Storage Management) or page 280 (CLU).
Migration has been set manually or by schedule.
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
379
Chapter 10: Troubleshooting
Corrective Action