Rebuild Operation - Asus DS300i User Manual

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

To enable Automatic Rebuild, see ―Making Background Activity Settings‖ on
page 69 (ASUS Storage Management) or page 257 (CLU).
To set Hot Spare Policy, see ―Making Spare Drive Settings‖ on page 173 (ASUS
Storage Management) or page 237 (CLU)

Rebuild Operation

During rebuild:
The alarm sounds a single short beep, repeated.
No warning icon displays over the Disk Array or Logical Drive in the Tree.
Management View reports the Disk Array's Operational Status as OK,
Rebuilding.
The drive carrier holding the rebuilding physical drive displays a green
Activity (lower) LED while the Status (upper) LED flashes green once per
second.
Figure 16. Disk drive carrier LEDs
During rebuilding, you can still read and write data to the logical drive. However,
fault tolerance is lost until the Disk Array returns to OK (not-rebuilding) status.
After a successful rebuild:
The alarm is silent
The Disk Array's Operational Status as OK
The rebuilt disk drive Status LED displays steady green
If your replacement disk drive was formerly part of a different disk
array or logical drive, you must clear the configuration data on the
replacement drive before you use it.
See page 143 (ASUS Storage Management) or page 223 (CLU).
.