Monitor Lamp Indicators; Managing The Indicated Problems - Panasonic PT-DS100XE Operating Instructions Manual

Dlp based projector
Hide thumbs Also See for PT-DS100XE:
Table of Contents

Advertisement

Monitor Lamp indicators

Monitor Lamp indicators

Managing the indicated problems

If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as
follow.
Attention
(STANDBY (R) / ON (G))
LAMP1/LAMP2 indicator
J
Lamp
indication
Indicates the time
Lighting in red
for replacing the
lamp unit.
Blinking in red
Lamp unit is not
(once)
installed.
Blinking in red
Error is detected
(3 times)
in the lamp circuit.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
z
108
- ENGLISH
Power indicator
Information
Did you notice a "REPLACE
z
LAMP" message on the screen
when turning on the projector
power supply?
Check the lamp unit
z
compartment.
Did you turn the power back
z
on immediately after turning it
off?
Some error has arisen in the
z
lamp circuit.
Check for fluctuation (or drop)
z
in the source voltage.
Lamp1 indicator (LAMP1)
Lamp2 indicator (LAMP2)
Check point
z
z
z
z
z
z
Temperature indicator (TEMP)
Filter indicator (FILTER)
Remedial measure
This lamp monitor lights up when the
lamp unit used hours have reached
2 800 hours (when [HIGH] is selected
as the [LAMP POWER] setting).
Request the dealer to replace the lamp
unit.
Install the lamp unit.
When lamp unit is installed and still
having the indicator lights, contact to
the dealer.
Wait until the lamp has cooled off, and
then turn on the power.
Turn off the MAIN POWER switch
using the procedure on page 40 and
consult the dealer.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dw90xePt-dz110xe

Table of Contents