Monitor Lamp Indicators; Managing The Indicated Problems - Panasonic PT-D5000E Operating Instructions Manual

Dlp based projector commercial use
Table of Contents

Advertisement

Monitor Lamp indicators

Managing the indicated problems

Indicators
Power indicator
Lamp1 (LAMP1) indicator
Lamp2 (LAMP2) indicator
Temperature (TEMP) indicator
Filter (FILTER) indicator
STANDBY(RED)/
STANDBY(RED)/
If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow.
1. Confirm the status of all indicators and projector, and switch off the projector in proper way.
2. Find out the cause of the problem by status of each indicator.
3. Follow the instruction for each indication below and solve the problem.
4. Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact your nearest dealer.
 LAMP1/LAMP2 indicator
Lamp
indication
Indicates the time for
Lighting in red
replacing the lamp unit
Blinking in red
Lamp unit is not installed.
once
Blinking in red
Error is detected in the
3 times
lamp circuit.
 TEMP indicator
Lamp
indication
Warm-up status
Lighting in red
High temperature inside.
(WARNING)
The filter is excessively
Blinking in red
dirty and the ventilation is
once
poor.
Blinking in red
High temperature inside.
twice
(Standby condition)
Blinking in red
Cooling fan has been
3 times
stopped.
E
NGLISH - 28
LAMP
LAMP
TEMP
TEMP
FILTER
FILTER
ON(GREEN)
ON(GREEN)
Information
• Did you notice a "REPLACE
LAMP" message on the screen
when turning on the projector
power supply?
• Check the lamp unit
compartment.
• Did you turn the power back on
immediately after turning it off?
• Some error has arisen in the
lamp circuit.
• Check for fluctuation (or drop) in
the source voltage.
Information
• Did you turn on the power when
the ambient temperature was
lower than approx. 0 °C (32 °F)?
• Check the ventilation port is
blocked.
• Is the room air temperature too
high?
• Was the temperature warning
indication displayed?
STANDBY(RED)/
STANDBY(RED)/
LAMP
LAMP
TEMP
TEMP
FILTER
FILTER
ON(GREEN)
ON(GREEN)
Check point
• This lamp monitor lights up when the lamp
unit used hours have reached 1 800* hours.
Request the dealer to replace the lamp unit.
* 2 800 hours for PT-D5000E only.
• Install the lamp unit.
• When lamp unit is installed and still having
the indicator lights, contact to the dealer.
• Wait until the lamp has cooled off, and then
turn on the power.
• Turn off the POWER switch of the projector
properly and contact your nearest dealer.
Check point
• Wait about 5 minutes in the current status.
• Install the unit in a location having an
ambient temperature from 0 °C (32 °F) -
45 °C (113 °F).
• Remove the object that is blocking the
ventilation port.
• Move the projector to a temperature of 0 °C
(32 °F) - 45 °C (113 °F) and the humidity of
20 % to 80 % (no condensation).
• Turn off the POWER switch of the projector
in proper way and contact the dealer.
• Turn off the POWER switch of the projector
in proper way and contact the dealer.
Remedial measure
Remedial measure