Error information page

J
When "Error (Detail)" is displayed on the status information screen, click it to display the error details.
Depending on the nature of the error, the projector may be placed in the standby mode for its own
z
protection.
When [FAILED] has appeared for an item
Q
Parameter
MAIN CPU BUS
FAN
INPUT AIR TEMPERATURE
OPTICS MODULE TEMPERATURE
AROUND LAMP TEMPERATURE
LAMP1 REMAIN TIME
LAMP2 REMAIN TIME
LAMP1 STATUS
LAMP2 STATUS
APERTURE (CONTRAST-SHUTTER)
INPUT AIR TEMP. SENSOR
OPTICS MODULE TEMP. SENSOR
AROUND LAMP TEMP. SENSOR
BATTERY
AIRFLOW SENSOR
COVER OPEN
ACF UNIT
FILTER REMAIN
BRIGHTNESS SENSOR
AC POWER
Note
The ACCESS ERROR INFORMATLION/ACCESS INFORMATION displays the past several thousand accesses/requests.
z
If many accesses/requests are made at a time, some of them may not be found in the information.
Check the ACCESS ERROR INFORMATION/ACCESS INFORMATION regularly.
z
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
The input air temperature is too high. It may be that the projector is being used in an
operating environment where the temperature is high such as near a heating appliance.
The temperature inside the projector is high. It may be that the projector is being used
in an operating environment where the temperature is high such as near a heating
appliance.
The temperature around the lamp is too high. It may be that the projector's ventilation
holes are blocked.
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
Trouble has occurred in the sensor used to detect the input air temperature.
Consult your dealer.
Trouble has occurred in the temperature detection sensor inside the projector.
Consult your dealer.
Trouble has occurred in the sensor used to detect the exhaust air temperature.
Consult your dealer.
The backup battery has been run out. Consult your dealer.
Trouble has occurred in the sensor used to detect the airflow volume.
Consult your dealer.
The lamp unit cover is not attached securely. Check the lamp unit compartment.
The air cleaning filter (ACF) is not installed or trouble has occurred. (
The filter remaining is getting less. (
Trouble has occurred in the brightness sensor. If the problem cannot be corrected by
turning the power off and on, consult your dealer.
AC power supply voltage input has dropped. Check that there is sufficient
electrical wiring capacity for the projector's power consumption requirements.
NETWORK menu
OK:
Normal operation
FAILED: Occurrence of trouble
Description
Æ
109 page)
Æ
110 page)
101
ENGLISH -