When WEB Control administrator rights password is not set
J
(Non-protect mode)
<Connection method>
1 )
Obtain the IP address and port number (Initial set value = 1024) of the projector and
make a request for connection to the projector.
You can obtain both IP address and port number from the menu screen of the projector.
IP address :
Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK STATUS]
Port number : Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK CONTROL] ⇒ [COMMAND PORT]
2 )
There is a response from the projector.
Response data
Data section
"NTCONTROL"
(ASCII string)
9 bytes
Mode : 0 = Non-protect mode
<Command transmission method>
Transmit by the following command format.
Transmitted data
'0'
0x30
1 byte
Receive data
'0'
0x30
1 byte
Error response
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
"ERRA"
Blank
' '
0x20
1 byte
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
Error message
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
4 bytes
Technical Information
Termination
Mode
symbol
'0'
(CR)
0x30
0x0d
1 byte
1 byte
Termination
Data section
Control command
(ASCII string)
Undefined length
Termination
Data section
Control command
(ASCII string)
Undefined length
Termination symbol
(CR)
0x0d
1 byte
ENGLISH -
symbol
(CR)
0x0d
1 byte
symbol
(CR)
0x0d
1 byte