Configuring the Switch External Alarms
This example configures alarm input 2 named door sensor to assert a major alarm when the door circuit
is closed and then displays the status and configuration for all alarms:
Switch(config)# alarm-contact 2 description door sensor
Switch(config)# alarm-contact 2 severity major
Switch(config)# alarm-contact 2 trigger closed
Switch(config)# end
Switch(config)# show env alarm-contact
Switch# show env alarm-contact
ALARM CONTACT 1
Status:
Description: test_1
Severity:
Trigger:
ALARM CONTACT 2
Status:
Description: door sensor
Severity:
Trigger:
ALARM CONTACT 3
Status:
Description: flood sensor
Severity:
Trigger:
ALARM CONTACT 4
Status:
Description:
Severity:
Trigger:
OL-23400-01
not asserted
critical
open
not asserted
major
closed
not asserted
critical
closed
not asserted
critical
closed