Configuring SyncE
Command
Step 3
controller BITS input applique E1 {2048KHz |
framing option linecode {ami | hdb3}
or
controller BITS input applique T1 framing {d4 | esf}
linecode {ami | b8zs}
Step 4
controller BITS output applique E1 {2048KHz |
framing options} linecode {ami | hdb3}
or
controller BITS output applique T1 framing {d4 | esf}
linecode {ami | b8zs} line-build-out length
Step 5
controller BITS shutdown
Step 6
end
Cisco ME 3800X and 3600X Switch Software Configuration Guide
6-8
Chapter 6
Purpose
(Optional) Configure the controller BITS input framing
and coding options.
For E1 input:
•
2048KHz—Select 2048 KHz input.
•
framing option—Select one of these options:
fas_crc4—FASCRC4
–
fas_nocrc—FAS
–
mfas_crc4—MFASCRC4
–
mfas_nocre—MFAS
–
For T1 input:
•
d4 linecode—D4
•
esf linecode—Extended superframe
linecode ami—AMI encoding
•
linecode b8zs—B8ZS encoding
•
(Optional) Configure the controller BITS output framing
and coding options.
For E1 output:
2048KHz—Select 2048 KHz input.
•
framing—Select one of these options:
•
fas_crc4—FASCRC4
–
fas_nocrc—FAS
–
–
mfas_crc4—MFASCRC4
–
mfas_nocre—MFAS
For T1 framing output:
d4 linecode—D4
•
esf linecode—Extended superframe
•
linecode ami—AMI encoding
•
linecode b8zs—B8ZS encoding
•
line-build-out length—Select a line length:
•
–
0-133ft
–
133-266ft
–
266-399ft
399-533ft
–
533-655ft
–
Shut down the BITS controller.