raidcom add rcu
Registers RCUs. The only registration method is the method in which no CU is specified (CU free).
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom add rcu -cu_free <serial#> <id> <pid>
-mcu_port <port> -rcu_port <port>
Options and parameters
Option
-cu_free
<serial#><id><pid>
-mcu_port <port>
-rcu_port <port>
Examples
Serial Number: Register P9500 of Serial number 64034 with CU free. Sets the port on MCU:
CL1-A and the port on RCU: CL1-B.
raidcom add rcu -cu_free 64034 R500 1 –mcu_port CL1-A –rcu_port CL1-B
raidcom delete rcu
Deletes the RCU.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom delete rcu -cu_free <serial#> <id> <pid>
Options and parameters
Option
-cu_free <serial#><id><pid>
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600,
P9500:R700
< pid> is used to set the path group ID (1-255).
Specifies a port number of the MCU.
Specifies a port number on the RCU (storage system port on the remote side).
Specify the port that the attribute is MCU Initiator port (MCU) or RCU Target port (RCU).
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk
Array:R600, P9500:R700
< pid> is used to set the path group ID (0-255).
raidcom add rcu 179