32 RCU Function

Add Path Operation

Example 1 (CU Free is used)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[RCU],Add Path,,Normal end,,,Seq.=xxxxx
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID}={99999,0x00,0x00,Default,4}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num of Port Pairs=8
Example 2 (CU Free is not used)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[RCU],Add Path,,Normal end,,,Seq.=xxxxx
+{S/N,MCU LDKC,MCU,RCU LDKC,RCU,SSID,Controller ID}={99999,0x00,0x3F,0x00,0x7F,0x0004,4}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num of Port Pairs=8
[RCU]
Remote Control Unit function
Add Path
Add Path operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 237 Add Path Operation
Item
S/N
MCU LDKC
RCU LDKC
Path Gr.ID
Controller ID
MCU
RCU
SSID
MCU Port
RCU Port
Num of Port Pairs

Add RCU Operation

Example 1 (CU Free is used)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[RCU],Add RCU,,Normal end,,,Seq.=xxxxx
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Min.Path,MIH Time(s),
Round Trip Time(ms),Incident,FREEZE}={99999,0x00,0x00,Default,4,08,015,001,
only to RCU host,Disable}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num of Port Pairs=8
Example 2 (CU Free is not used)
Description
Indicates a serial number of the device.
The LDKC number of the connected LDKC.
The LDKC number of the paired LDKC.
The path group ID. When the path group ID is default setting, Default is output.
The controller ID.
The CU number of the connected CU.
The CU number of the paired CU.
The SSID.
The port number of MCU.
The port number of RCU.
The number of port pairs set.
Table 237 (page
193).
Add Path Operation 193