Installing The Rail Kits And Mounting The Hpe Storeeasy 1000 Storage In A Rack; Installing The Rail Kits And Mounting The System In A Rack For Hpe Storeeasy 1460 Storage, Hpe Storeeasy 1660 Storage, Hpe Storeeasy 1660 Expanded Storage, And Hpe Storeeasy 1860 Storage - HP HPE StoreEasy 1000 Getting Started Manual

Table of Contents

Advertisement

2. Installing the rail kits and mounting the HPE StoreEasy 1000
Storage in a rack
Procedure
1. Installing the rail kits and mounting the system in a rack for HPE StoreEasy 1460 Storage, HPE StoreEasy 1660
Storage, HPE StoreEasy 1660 Expanded Storage, and HPE StoreEasy 1860 Storage
2. Installing the rail kits and mounting the system in a rack for HPE StoreEasy 1560 Storage
Installing the rail kits and mounting the system in a rack for HPE StoreEasy 1460
Storage, HPE StoreEasy 1660 Storage, HPE StoreEasy 1660 Expanded Storage, and HPE
StoreEasy 1860 Storage
You can install the rail kit and mount the following systems:
HPE StoreEasy 1460 Storage
HPE StoreEasy 1660 Storage
HPE StoreEasy 1660 Expanded Storage
HPE StoreEasy 1860 Storage
Prerequisites
CAUTION: Electrostatic Discharge (ESD) can damage the electronic components. Ensure that you are properly
grounded (earthed) before beginning any installation procedure.
This installation must be performed by qualified individuals having knowledge of the procedures, precautions, and
equipment hazards that contains hazardous electrical circuits.
WARNING:
The rail kits, when installed, form only a shelf for the HPE StoreEasy 1000 Storage to rest on. The HPE
StoreEasy 1000 Storage is not attached to the rail by any other means. Use extreme caution when pulling the
HPE StoreEasy 1000 Storage out from the rack. The storage system can slip and fall, which may cause injury to
the operator or damage to HPE StoreEasy 1000 Storage. HPE is not responsible for any damage or injury
caused by mishandling of HPE StoreEasy 1000 Storage.
Ensure that the rack is leveled and stable before working on the rack. The leveling jacks (feet) must extend to
the floor and the full weight of the rack must rest firmly on the floor.
Ensure that the rack has anti-tip measures such as, floor-bolting, anti-tip feet, ballast, or a combination of the
measures, as specified by the rack manufacturer and applicable codes in place.
Ensure that sufficient personnel are available to support one or more products during the installation process.
HPE recommends you to use an appropriate lifting device as an installation aid.
Ensure that the rack is loaded from bottom to top, with the heaviest appliances at the bottom to make the rack
steady.
Avoid overloading the branch circuit that provides power to the rack. The total rack load must not exceed 80
percent of the branch circuit rating.