Chapter 8

Preparing the Rack

The outer-rail assemblies must be released after shipment and the columns must
be marked before mounting the outer-rail assemblies. Once the outer-rails are
correctly mounted, then the HP Netserver LP 1000r can be installed into the rack.
A template is not provided because the Netserver is exactly one EIA unit high and
can only fit into one EIA unit, but not across two EIA units.
NOTE
The HP Netserver weighs 32 lbs. (14.5 kg.) fully loaded. It is
not necessary to use two people when placing the Netserver
into the rack, but it may be helpful.

HP Netserver Rack Mount Parts List

Ensure the rack-mounting kit provided with the HP Netserver contains the
following parts:
Table 8-1. Parts for Rack Mount Kit
Quantity
2
Outer-rail assemblies

Releasing Outer-Rail Assemblies

This is only required the first time the outer-rail assemblies are shipped. The
outer-rails are compressed for shipping and held in place with two 10-mm nuts.
These nuts must be turned turn to release the spring assembly and then turned
back to hold the spring assembly in place with freedom to move back and forth.
See Figure 8-2.
1. Turn both nuts counterclockwise (CCW) ¾ of a turn to release the spring
assembly.
2. Turn both nuts back clockwise (CW) ¼ of a turn to hold the spring
assembly in place.
The spring assembly must be able to move freely back and forth to aid in
installation of the outer-rails into the rack.