HP D5970A - NetServer - LCII Guía Del Usuario page 48

Hp netserver lp 1000r user guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 5
Figure 5-5. Inserting PCI Board-Riser Board
12. Insert the PCI board and riser board into the PCI connector on the system
board. See Figure 5-5.
13. Secure the PCI board into the slot opening between the two tabs and close
the latch. See Figures 5-4 and 5-5.
14. If you have a longer PCI board, you must use the board clamp to install the
board into the Netserver. See Figure 5-6.
a. Raise the board clamp before installing the PCI board. See Figure 5-6.
b. Install the PCI board into the Netserver, securing the PCI board into the
slot opening between the two tabs. See Figures 5-4 and 5-5.
c. Lower the PCI board onto the tab rests. See Figure 5-6.
d. Close the latch and then close the board clamp onto the edge of the PCI
board. See Figure 5-6.
15. When you have completed the PCI aboard installation, close the Netserver
and return it to the rack where power can be applied.
42
Latch
Installing Additional Boards
Riser Board
Installed
PCI Slot

Advertisement

Table of Contents
loading

Table of Contents