HP Visualize J5000 - Workstation Service Handbook page 68

J class workstation
Hide thumbs Also See for Visualize J5000 - Workstation:
Table of Contents

Advertisement

Table 4–1. I/O Failure Codes (Cont.)
FRU
Ostat
Code
Selftest SIMM 1
FLT
7f13
Selftest SIMM 0
FLT
7f20
Selftest SIMM 6
FLT
7f21
Selftest SIMM 5
FLT
7f22
Selftest SIMM 3
FLT
7f23
Selftest SIMM 1
FLT
7f30
Selftest SIMM 7
FLT
7f31
Selftest SIMM 4
FLT
7f32
Selftest SIMM 2
FLT
7f33
Format is – FLT 8xye, where x=slot, y=bus, e=error
Selftest Sys Bd
FLT
8001
Selftest Sys Bd
FLT
8002
Selftest Sys Bd
FLT
800c
TEST
8300
TEST
8301
8302
TEST
8306
TEST
8307
TEST
8308
WARN
8308
Codes associated with the execution of console/boot iodc will use the codes defined
below. The value of Y shows the failure:
Y = 3
CHASSIS_ERR_READING_IODC_BYTES
Y = 4
CHASSIS_ERR_READING_EINIT
Y = 5
CHASSIS_ERR_EXEC_EINIT
Y = 6
CHASSIS_ERR_READING_EIO
Y = 7
CHASSIS_ENTRY_IO_ERR
Y = 8
CHASSIS_INVALID_DEV_CLASS
WARN
84xY
WARN
850Y
WARN
851Y
WARN
852Y
WARN
853Y
WARN
854Y
4–18
Troubleshooting
Name
CHASSIS_MEM_FRU_ID_01
CHASSIS_MEM_FRU_ID_10
CHASSIS_MEM_FRU_ID_16
CHASSIS_MEM_FRU_ID_15
CHASSIS_MEM_FRU_ID_13
CHASSIS_MEM_FRU_ID_11
CHASSIS_MEM_FRU_ID_17
CHASSIS_MEM_FRU_ID_14
CHASSIS_MEM_FRU_ID_12
CHASSIS_IOA_RAM_TEST
CHASSIS_IOA_TLB_TEST
CHASSIS_IOA_DMA_TEST
CHASSIS_LASI_TEST_SCSI
CHASSIS_LASI_TEST_LAN
CHASSIS_LASI_TEST_KYBD
CHASSIS_WAX_MAP_TEST
CHASSIS_WAX_ID_TEST
CHASSIS_WAX_8042_SELFTEST
CHASSIS_WAX_8042_WARN
Notes
Error in SIMM Pair 1
Error in SIMM Pair 0
Error in SIMM Pair 6
Error in SIMM Pair 5
Error in SIMM Pair 3
Error in SIMM Pair 1
Error in SIMM Pair 7
Error in SIMM Pair 4
Error in SIMM Pair 2
x = IOA number
x = IOA number
x = IOA number
Graphics in logical slot
x=0thru3
LASI rs232 port
EISA rs232 port
LASI ps2, port 0
LASI ps2, port 1
EISA HIL

Advertisement

Table of Contents
loading

This manual is also suitable for:

9000 j class

Table of Contents