Troubleshooting Frus - HP Rx2620-2 - Integrity - 0 MB RAM Service Manual

User service guide
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

Table 5-1 Troubleshooting FRUs
Problem or
Symptom
No indication of
housekeeping
voltage present
when AC is
connected and
power switch is
in the off
position.
System does not
power on when
display panel
Power switch is
turned on.
No EFI Main
Menu prompt.
Cannot boot to
operating
system.
98
Troubleshooting
Problem
Normal Functioning
Indicators
Indicators
Standby LED is
Power LED Off.
off when AC is
Power LED on iLO
plugged into
MP card (if
server. BMC
installed) should be
"heartbeat" not
lit solid green.
flashing. Both
Standby LED on
LEDs are
system board is on
located on the
steady.
system board,
see System
BMC "heartbeat"
Board LEDs
LED on system
later in chapter.
board is flashing.(if
installed) should be
lit solid green.
Display panel
Power switch on.
Power LED
Power LED on
stays off when
steady green.
power is turned
System LED is off.
on.
System LED
might be
flashing yellow
(Attention
indication).
Display panel
Display panel
power LED is
power LED is
not steady
steady green.
green.
System events are
No server
being displayed at
events are being
the console.
displayed at the
EFI Main Menu
console.
prompt.
There is no EFI
Main Menu
prompt at the
console.
Boot error
Operating system
messages.
prompt.
System LED
Operating system
flashing.
boot messages.
System LED on
steady green.
Troubleshooting Steps
1. AC must be present. Check that
PDU is plugged in.
2. Ensure there is a working
power supply. The LED on the
supply should be lit.
3. Check for an EFI shell prompt
(CTRL B) at console).
1. Ensure there is a working
power supply. The LED on the
supply should be lit.
2. Verify that standby voltage is
present. Check that the STBY
LED on the system board is lit.
3. Verify that the baseboard
management controller is
functioning. Check the
heartbeat (BMC) LED on the
system board is lit.
4. Check server event log (SEL).
Look for event log detail = Low
Voltage DC power. This
indicates a failure of one of the
CPU power pods.
1. Check that the console is
properly connected and can
communicate with the BMC.
Press (CTRL B) to access the iLO
MP login prompt.
2. Check SEL.
Look for entries related to:
• Processors
• Processor Support Modules
(Also known as power pods).
• Memory
3. Check for red LED on the iLO
MP card if installed. If red, the
problem is with the iLO MP.
4. Reduce to minimum
configuration and troubleshoot
from there.
1. Check console messages. Did
server hang?
2. Check SELs for possible
problem indication.
3. Run ODE diagnostics.
Potential FRUs
No AC present
Power Supply
Power Distribution
System board
Display board
Missing FRU
Power Supply
CPU power pod
System board
Intrusion switch on
chassis (cover not
completely closed)
Processors
Processor Support
Modules
Memory
System board
Console
Corrupt operating
system
Hard Drive
Disk drive cage
backplane
SCSI interface on
system board
Processor

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx2620