Reinstalling The Power Connectors - HP Rx2620-2 - Integrity - 0 MB RAM Service Manual

User service guide
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

Figure 4-57 Reinstalling the Power Connectors
9.
Replace the following server components:
PCI card cage. See
Server fans. See
Processors. See
Processor airflow guide. See
Memory DIMMs. See
Memory airflow guide. See
10. Replace the top metal cover. See
11. Reconnect all of the power and external cables.
12. Power on the server. See
13. Boot to EFI.
14. Respond YES to prompts regarding copying information onto the new I/O baseboard.
Primary system ID values are undefined.
Do you want to copy the valid system ID values to the new board? (y/[n])
Y
15. Enter service mode.
Shell> sysmode service
Current System Mode: ADMIN
You are now in SERVICE mode.
16. Use the sysset command to enter the product data:
Shell> sysset prodname "server rx2620"
17. Use the syssetcommand to verify all values are set:
Shell> sysset
System Information:
Manufacturer: hp
Product Name: server rx2620
Product Number: AB332A
Secondary Product Number is Identical
Serial number: US51884101
Secondary Serial Number is Identical
86
Removing and Replacing Components
"Replacing the PCI Card Cage" (page 72)
"Replacing a Server Fan" (page 48)
"Replacing a Processor" (page 65)
"Replacing the Processor Airflow Guide" (page 56)
"Installing DIMMs" (page 59)
"Replacing the Memory Airflow Guide" (page 54)
"Replacing the Top Metal Cover" (page
"Powering On the Server" (page
44).
38).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx2620

Table of Contents