Command Line Interface; Command Line Interface Menu; Troubleshooting Example Using Cli; Bmc Faults - HP Rx2620-2 - Integrity - 0 MB RAM Service Manual

User service guide
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

Table 5-19 BMC Faults
System LED
LED 1
Flashing
RED
Red
Flashing
RED
Red
Table 5-20 Temperature Faults
System LED
LED 1
Flashing
RED
Red
Table 5-21 Power Supply Errors
System LED
LED 1
Flashing
OFF
Red
Flashing
GREEN
Red
Flashing
OFF
Red
Flashing
GREEN
Red

Command Line Interface

The baseboard management controller (BMC) is accessable by means of the BMC console
commands, or command line interface (CLI). The commands are similar to the iLO MP commands
but are slightly less interactive.

Command Line Interface Menu

The CLI provides the following menu selections:
date: Date displayhelp: List available commandsipmi: Send IPMI cmdloc: System locator
LEDpasswd: Change passwordpc: Power controlpr: Power restore policyps: Power statusrs:
System resetsl: Show logssr: Display firmware revisionstc: System resetexit: Exit

Troubleshooting Example Using CLI

This example uses the CLI and the SEL to display error message indicating that no memory is
installed.
cli>sl e
#
Sev Generator/Sensor Description
---- - ---------------- ------------ ----------- --------------------------
00A0 - SFW
00B0 7 CPU0
00C0 7 CPU0
00D0 - SFW
108
Troubleshooting
LED 2
LED 3
LED 4
GREEN
RED
OFF
GREEN
RED
GREEN
LED 2
LED 3
LED 4
GREEN
GREEN
RED
LED 2
LED 3
LED 4
RED
OFF
RED
RED
OFF
RED
RED
GREEN
RED
RED
GREEN
RED
FW error
Mem no DIMMs
Mem no DIMMs
FW error
Problem
Solution
BMC firmware
Turn off and unplug the server. Wait
is damaged
20 seconds, then plug in and restart
the server. If the error repeats, replace
the base unit.
System board
View the SEL for additional
FRU inventory
information.
device
inaccessible
Problem
Solution
External air
Make sure nothing is blocking the
temperature too
server airflow and locate your server
high
in an air-conditioned room.
Problem
VRM or power pod
fault
Power Supply 1 fault
Power Supply 2 fault
12V out of range
(power supply
interface fault)
Event ID
Data, Timestamp
00-0F:70:40 3F:--
000D0
DT 00
000D0
Time
00-0F:70:40 3F:--
Solution
View the SEL for additional
information.
2003-10-31 22:29:06
0000000000000000
2003-10-31 22:29:06
2003-10-31 22:29:06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx2620

Table of Contents