To identify a degraded component using the CLI:
1.
Type: SET DISPLAY EVENTS [BAY | ENCLOSURE | ON | OFF] to ON.
2.
Type: SET DISPLAY EVENTS ENCLOSURE ALL ON.
3.
Type: SET DISPLAY EVENTS BAY ALL ON.
4.
Type the appropriate commands:
SHOW ENCLOSURE FAN [<fan number> | ALL]
This command displays the status, redundancy, partner, speed, and part number for one or all fans
in the enclosure.
SHOW ENCLOSURE INFO
This command displays the enclosure name, type, part number, serial number, and asset tag
number; the Integrated Administrator software and hardware version; the MAC address of the
Integrated Administrator, and the interconnect tray type, part number, and serial number.
SHOW ENCLOSURE POWERSUPPLY [<power supply number> | ALL]
This command displays the status, AC input status, capacity, input voltage range #1 (Volts), input
voltage range #2 (Volts), input frequency range (Hz), part number, serial number, and hardware
revision for one or both power supplies in the enclosure.
SHOW ENCLOSURE STATUS
104 Chapter 8 Performing Common Administrative Tasks