Page 6
4-4-11 HP_DeviceIndication: Controller Redundancy has been lost ............. 115 4-4-12 HP_DeviceIndication: Controller Redundancy has been restored ..........117 4-4-13 HP_DeviceIndication: Controller Battery Status Change - OK ........... 119 4-4-14 HP_DeviceIndication: Controller Battery status changed to not fully charged ......122 4-4-15 HP_DeviceIndication: Controller Battery status changed to Failed ..........
Page 8
6-2-10 Enclosure Power Supply status changed to Non Redundant ............. 208 6-2-11 Enclosure Power Supply Status changed to OK (Redundant) ............ 210 6-2-12 Enclosure Power Supply Status changed to Redundant Degraded ..........212 6-2-13 Enclosure Temperature sensor Status changed to OK .............. 214 6-2-14 Enclosure Temperature sensor status changed to Warning ............
Page 9
8-3-17 SMX_ProcessorLocation ....................... 262 8-3-18 SMX_ProcessorElementLocation .................... 264 Supported indications ........................264 8-4-1 HP_DeviceIndication: Processor Failed Post ................265 8-4-2 HP_DeviceIndication: Processor Disabled by BIOS or EFI ............266 8-4-3 HP_DeviceIndication: Processor Predicted to fail ..............267 System Fan ..........................268 Overview .............................
Overview The HP Insight Management WBEM Providers supply system management data through HP integrated VMware ESXi framework for HP ProLiant server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires HP integrated VMware ESXi. Overview 13...
Ethernet port Overview The following profiles are implemented, and files are installed by this provider. Table 2-1 Overview Implemented Profiles • DMTF: Ethernet Port Profile (DSP1014) v. 1.0.0 • DMTF: Host LAN Network Port Profile (DSP1035)1.0.0 • HP Location Profile 1.0 •...
• SMX_RemoteAccessAvailableToIPEndpoint • SMX_RemoteServiceHostedAccessPoint • SMX_EthernetStatistics • SMX_EthernetPortToStatisticalData • SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • SMX_EthernetElementFirmwareIdentity • SMX_EthernetCollection • SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection SMX_EthernetPort 2-3-1 SMX_EthernetPort implements the class HP_EthernetPort and describes capabilities and characteristics of each EthernetPort in a monitored system. Table 2-2 Class: SMX_EthernetPort Property name...
Page 16
Table 2-2 Class: SMX_EthernetPort StatusDescriptions StatusDescriptions [0] per OperationalStatus[0]: • Unknown • • Degraded • Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort:<InstanceNum> IdentifyingDescriptions None or HPQ: Spare part number if available OtherIdentifyingInfo None or part number text if available SystemName...
Table 2-3 Class: SMX_EthernetDevice Property name Property implementation HP_EthernetDevice GroupComponent ref: SMX_ComputerSystem (the computer system in which this Ethernet Port resides) PartComponent ref: SMX_EthernetPort (the instance of Ethernet Port in this ComputerSystem) SMX_EthernetLANEndpoint 2-3-3 SMX_EthernetLANEndpoint implements the class HP_EthernetLANEndpoint and describes a communication endpoint which, when its associate interface is connected to a LAN, might send and receive data frame.
Table 2-4 Class: SMX_EthernetLANEndpoint Property name Property implementation SystemCreationClassName SMX_ComputerSystem CIM_ProtocolEndpoint Description Text representing of what the operating system labels this endpoint. For example: eth3 On Windows operating systems: Local Area Connection 2 ElementName LAN Endpoint info for OS Exposed Ethernet Port informatiom.
Table 2-6 Class: SMX_EthernetLANHostedAccessPoint Property name Property implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent ref: SMX_EthernetPort Dependent ref: SMX_EthernetPortLANEndpoint SMX_EthernetPortController 2-3-6 SMX_EthernetPortController implements the class HP_BladeEnclosureFW and is a logical device corresponding to a hardware Ethernet network controller. Table 2-7 Class: SMX_EthernetPortController Property name Property implementation CIM_ManagedElement...
Table 2-7 Class: SMX_EthernetPortController Property name Property implementation ControllerType 2 (Ethernet) ControllerVersion Hardware revision number of the controller or 0 if unknown SMX_EthernetPortControllerEthernetPort 2-3-7 SMX_PortControllerEthernetPort implements the class HP_PortControllerEthernetPort and associates an Ethernet Port Controller to its controlled Ethernet Ports. Table 2-8 Class: SMX_EthernetPortControllerEthernetPort Property name...
Table 2-9 Class: SMX_EthernetPortControllerPhysicalPackage Property name Property implementation CanBeFRUed Boolen describing if this individual physical package can be replaced in the field. • True if PCI card • False if embedded device on Motherboard CreationClassName SMX_EthernetPortControllerPhysicalPackage Description Product Name For example: Controller (<num_ports>-port): Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21)
SMX_EthernetControllerLocation 2-3-10 SMX_EthernetControllerLocation implements the class HP_EthernetControllerLocation. It describes the location information of the Ethernet Contoller Physical Package or card. Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation CIM_ManagedElement ElementName Product Name. For Example: 2 port controller: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21) CIM_Location Name...
Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation LocationInfoDesc Array of enums describing values at comparable index in LocationInformation array. LocationInfoDesc[0] per LocationInfornation[0]. Values for embedded devices: • 17 (Embedded) non-blade, non-cellular system & visible RJ45 • 14 (Blade Bay) for blades with LAN on Motherboard •...
Page 25
Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName IP Protocol Endpoint info for OS Exposed Ethernet Port informatiom. For example: IP Protocol Endpoint(<instanceNum>) for : 82546GB Gigabit Ethernet Controller port <portNumber> For ESXi, IP Protocol Endpoint information for management network logical interface name.
Page 26
Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation AddressOrigin How the Address was assigned to this IP Protocol Endpoint. • 0 (Unknown) • 3 (Static) • 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address.
SMX_IPBindsToEthernetLANEndpoint 2-3-13 SMX_IPBindsToEthernetLANEndpoint implements the class HP_IPBindsToEthernetLANEndpoint and associates an instance of an IP ProtocolEndpoint with its representative Ethernet LAN Endpoint instance. NOTE: Currently not implemented on VMware ESXi platform. The association information between IP addresses and physical NICs is not available to OEM providers on ESXi. Table 2-14 Class: SMX_IPBingsToEthernetLANEndpoint Property name...
Table 2-16 Class: SMX_RemoteServiceAccessPoint Property name Property implementation CIM_ManagedElement ElementName A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name> CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_RemoteServiceAccessPoint Name A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name>...
Table 2-17 Class: SMX_RemoteAccessAvailableToIPEndpoint Property name Property implementation CIM_RemoteAccessAvailableToElement IsDefault Boolean true if only one default and only one gateway are present. In some systems, you might have order of access constraints if multiple gateways are present. Check OrderOfAccess property for gateway priorities. OrderOfAccess 0 (default) indicates ordering does not apply, othewise numbers indicate priority order of access.
Table 2-19 Class: SMX_EthernetStatistics Property name Property implementation Caption For Ethernet Ports, same as associated EthernetPort.Caption. Description A description of the instance with unique port number for each port on a particular controller, for example: Ethernet port <PortNumber> on ethernet controller <controller_id>...
Table 2-20 Class: SMX_EthernetPortStatisticalData Property name Property implementation CIM_ElementStatisticalData Key:ManagedElement ref:SMX_EthernetPort Key:Stats ref:SMX_EthernetStatistics HP_EthernetPortStatisticalData SMX_EthernetPortControllerSoftwareIdentity 2-3-20 SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. NOTE: Currently implemented only on VMware ESXi platform. Table 2-21 Class: SMX_EthernetPortControllerSoftwareidentity Property name...
Table 2-22 Class: SMX_EthernetPortControllerFirmwareIdentity Property name Property implementation CIM_ManagedElement Caption Ethernet Port Controller Firmware Description Ethernet Port Controler Firmware details for Model Name, where Model name is the Model name of the Ethernet Adapter. ElementName PCI Vendor Id: Device Id CIM_ManagedSystemElement Name Ethernet Port Controler Firmware details for Model...
SMX_EthernetElementFirmwareIdentity 2-3-23 SMX_EthernetElementFirmwareIdentity implements the class CIM_ElementSoftwareIdentity. It represents the association between SMX_EthernetPortController and SMX_EthernetPortControllerFirmwareIdentity. Table 2-24 Class: SMX_EthernetElementFirmwareIdentity Property name Property implementation CIM_ Dependency Antecedent ref:SMX_EthernetPortControllerFirmwareIdentity Dependent ref:SMX_EthernetPortController CIM_ElementSoftwareIdentity ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_EthernetCollection 2-3-24 SMX_EthernetCollection implements the class HP_EthernetCollection. It represents the collection of all Ethernet Ports.
SMX_EthernetMemberOfCollection 2-3-25 SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection. Table 2-26 Class: SMX_EthernetMemberofCollection Property name Property implementation CIM_ MemberOfCollection Collection ref:SMX_EthernetCollection Member ref:SMX_EthernetPort CIM_MemberOfPolicyCollection Included Writeable boolean property indicating if the ethernet port instance referenced by Member will contribute status to the SMX_EthernetCollection.
Page 35
Table 2-28 Class: Provider Indication Common Properties Property name Property implementation IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. For example, 01.05.00 NetworkAddresses Contains a list of all the IP addresses of the computer...
Page 36
Table 2-29 HP_AlertIndication: Network Interface Connectivity Lost Property name Property implementation AlertType 2 (Communications Alert) EventID ProviderName HP Ethernet RecommendedActions View the Ethernet Port status in HP Systems Insight Manager (SIM). View the System Event Log for additional information. HP_AlertIndication Summary The Network interface has lost connectivity.
PCI Device Provider Overview This provider implements the profiles listed to support PCI devices installed in HP servers. The following table details the profiles implemented and files installed by this provider. Table 3-1 Overview Implemented Profiles • DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 •...
Page 39
Table 3-2 Class: SMX_PCIDevice Property name Property implementation CreationClassName SMX_PCIDevice DeviceID Unique identifier for this PCI device instance SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SXM_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PCIController Capabilities An array of integers that indicates controller capabilities.
Table 3-2 Class: SMX_PCIDevice Property name Property implementation CacheLineSize Specifies the system cache line size. CIM_PCIDevice DomainNumber The domain/segment number where this PCI device resides. BusNumber The bus number where this PCI device resides DeviceNumber The device number assigned to this PCI device for the FunctionNumber The function number for this PCI device PCIDeviceID...
Table 3-3 Class: SMX_PCICard Property name Property implementation Description PCI Card <cardNum> ElementName PCI Card <cardNum> CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) PackageType 9 (Module/Card) VendorCompatibilityStrings HPQ:PCICard CIM_Card HostingBoard False HP_PCISlotCard SMX_PCISlot 3-3-3 SMX_PCISlot represents PCI device slots on HP Servers. There is an instance of this class for each PCI slot in the system (whether the slot is occupied or not).
Page 42
Table 3-4 Class: HP_PCISlot Property name Property implementation PoweredOn True —If slot is powered on False—If slot is not powered CIM_PhysicalConnector ConnectorLayout 7 (Slot) ConnectorPinout PCI—If 33 MHz PCI slot PCI-66—If 66 MHz PCI slot PCI-X—If PCI-X slot PCI Express—If PCI Express slot PCI Express Mezzanine—If in-blade Mezzanine slot ConnectorType 43 (PCI)—If this is a 33 MHz PCI slot...
SMX_PCICardInSlot 3-3-4 SMX_PCICardInSlot is used to represent an association between SMX_PCICard and SMX_PCISlot that contains this PCI card. Table 3-5 Class: SMX_PCICardInSlot Property name Property implementation Antecedent References SMX_PCISlot Dependent References SMX_PCICard SMX_RealizesPCIDevice 3-3-5 SMX_RealizesPCIDevice is used to represent an association between SMX_PCIDevice and SMX_PCICard that realizes this PCI device.
SMX_PCISlotLocation 3-3-8 SMX_PCISLotLocation is used to model PCI slot locations on HP Servers. The Windows specific implementation class is SMX_PCISlotLocation. Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag. ElementName Same as ElementLocationTag. CIM_Location Name Unique identifier of the form:...
Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation LocationInfoDesc for BladeSystem servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0 & 1. LocationInfoDesc[0] per LocationInfornation[0]. Blade servers 1 (Mezzanine Slot) 14 (Blade) LocationInfoDesc for all other servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0.
Smart Array Overview The HP Smart Array data sheet describes both host based Smart Array HBAs and externally attached MSA enclosures, such as MSA60/70. NOTE: This provider excludes externally attached MSA controllers, such as MSA500 and fibre attached devices, for example MSA1000 or MSA The following profiles are implemented, and the following files are installed by this provider.
Page 47
Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation ElementName Controller/Storage System name and location Examples: Smart Array in Slot=3, for internal Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement OperationalStatus[0] Overall status of the Array System and attached devices.
Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation Dedicated Dedicated[0]: 3 (Storage) Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name OtherIdentifyingInfo Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard.
Table 4-3 Class: SMX_SAArrayController (CIM_ComputerSystem) Property name Property implementation Name Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard. PCISLO-<Slot number> is reported if there is no Serial Number for device is local.
Page 50
Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description (for example, Logical Volume 1 (RAID 1+0) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume. CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice...
Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status. DMTF defined value is populated in index[0] and extended status is poplulated in index[1] per HP Smart Array Profile. OSName Corresponding OS name for this volume.
Table 4-5 Class: SMX_SADiskDrive (CIM_DiskDrive) Property name Property implementation HPSA_DiskDrive DriveConfiguration See HP Smart Array Profile DriveHasMNPData See HP Smart Array Profile DriveInterface See HP Smart Array Profile DrivePlacement See HP Smart Array Profile DriveRotationalSpeed See HP Smart Array Profile NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed...
Table 4-6 Class: SMX_SAStorageExtent (CIM_StorageExtent) Property name Property implementation SystemName SMX_SAArraySystem.Name CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] Indicates extended status for the disk drive Possible values: 2 (None) 11 (Rebuild—Disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial...
Table 4-7 Class: SMX_SADiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware SMX_SAPhysicalPackage 4-3-7 SMX_SAPhysicalPackage implements the HPSA_PhysicalPackage class and represents the overall physical package for the array system as a whole. There is one instance per HBA or Storage Subsystem.
Table 4-9 Class: SMX_SAArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, Smart Array in Slot=3 for internal or Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement Name Controller Serial number...
Table 4-10 Class: SMX_SADiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Model Drive model string PartNumber N/A—Not Available in this implementation SerialNumber Drive serial number Opaque Key Version N/A—Not Available in this implementation CIM_PhysicalPackage HotSwappable TRUE—Drive is hot swappable FALSE—Drive is not hot swappable RemovalConditions 2 (Not Applicable) HPSA_...
Table 4-11 Class: SMX_SAStorageEnclosure (HP_StorageEnclosure) Property name Property implementation Opaque key Version N/A—Not Available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure Location See HP Storage Enclosure Profile HPSA_StorageEnclosure SMX_SAStorageEnclosureProcessor 4-3-11 SMX_SAStorageEnclosureProcessor HPSA_StorageEnclosureProcessor class and represents the management processor within a Storage Enclosure.
Table 4-13 Class: SMX_SAPortController (CIM_PortController) Property name Property implementation CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_Controller CIM_PortController ControllerType 1 (Other) OtherControllerType SCSI – Parallel SCSI HBA SAS/SATA – SAS/SATA HBA HPSA_PortController SMX_SADAPort 4-3-13 SMX_SADAPort implements the HPSA_DAPort class and represents the front-end port for an HBA in the host system.
Table 4-17 Class: SMX_SAPrimordialPool (CIM_StoragePool) Property name Property implementation CIM_StoragePool InstanceID Opaque key PoolID Controller serial number Primordial Always set to TRUE RemainingManagedSpace Remaining raw space on controller. This is calculated by summing the remaining space on all drives attached to the controller.
SMX_SAMediaAccessStatData 4-3-18 SMX_SAMediaAccessStatData implements the HPSA_MediaAccessStatData and represents the Monitoring and Performance data counters on HP Disk Drives. Table 4-19 SMX_SAMediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation CIM_ManagedElement CIM_StatisticalData InstanceID Opaque key SampleInterval CIM_MediaAccessStatData HPSA_MediaAccessStatData AbortedCommands See HP Smart Array Profile BadTargetErrors See HP Smart Array Profile DRQTimeOuts...
SMX_SAStorageSetting 4-3-19 SMX_SAStorageSetting implements the HPSA_StorageSetting class and represents the current raid configuration for a Storage Volume. There is one instance per Storage Volume. Table 4-20 Class: SMX_SAStorageSetting (CIM_StorageSetting) Property name Property implementation CIM_ManagedElement ElementName RAID <n>, where <n> is the raid description •...
SMX_SADriveCage 4-3-20 SMX_SADriveCage implements the HPSA_DriveCage class and represents the drive cage assembly and backplane within a storage enclosure. Multiple instances might occur within a duplexed enclosure. Table 4-21 Class: SMX_SADriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <n>, where <n> is the name of the port this drive cage is connected For example, Port J3 CIM_ManagedSystemElement...
Table 4-22 Class: SMX_SASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation ElementName Controller name and location (for example, Smart Array in Slot=3, or Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller ) CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault...
Table 4-24 Class: SMX_SARedundancySet (CIM_RedundancySet) Property name Property implementation RedundancyStatus 2 (Fully Redundant) 4 (Redundancy Lost) TypeOfSet[0] 4 (Sparing) HPSA_RedundancySet SMX_SAStorageRedundancySet 4-3-24 SMX_SAStorageRedundancySet implements the HPSA_StorageRedundancySet class and represents disk sparing aspect of a RAID configuration. There is an instance for every raid set that has spare drives configured.
Table 4-26 Class: SMX_StorageSpecificCollection (HP_GroupHostedCollection) Property name Property implementation Caption Storage Array Consolidated Status Description Storage Array Consolidated Status ElementName Storage Array Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Consolidated status for all array controllers. See section 9.10 Consolidated status example of HP Smart Array profile for details on how this value is calculated.
Table 4-27 Class: SMX_SADriveCageLocation (HP_Location) Property name Property implementation HPSA_DriveCageLocation SMX_SAArraySystemLocation 4-3-27 SMX_SAArraySystemLocation implements the HPSA_ArraySystemLocation class and represents a location string for the array system. Table 4-28 Class: SMX_SAArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location Examples: •...
Table 4-28 Class: SMX_SAArraySystemLocation (HP_Location) Property name Property implementation LocationInformation[0] For internal HBAs: PCI Slot number Examples: • 3—PCI Slot 3 • 0—Embedded on Motherboard Not Required for External Storage systems LocationInfoDesc[0] 3 (PCI Slot)—For internal HBAs Not required for External Storage Systems HPSA_ArraySystemLocation SMX_SADiskDriveLocation 4-3-28...
Page 72
Table 4-30 Class: SMX_SArrayControllerLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location Examples: • Smart Array in Slot=3, for internal • Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller Description Controller name and location Examples:...
SMX_SAStorageCapabilities 4-3-30 SMX_SAStorageCapabilities implements the HPSA_StorageCapabilities class and represents the possible capabilities of a Storage Pool. Table 4-31 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation CIM_ManagedElement ElementName For Primodial Pools: Controller name and location Examples: • Smart Array in Slot=3, for internal •...
Table 4-31 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation PackageRedundancyMax 0 (When number of drives <= 1) 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) PackageRedundancyMin HPSA_StorageCapabilities SMX_SAProduct 4-3-31 SMX_SAProduct implements the HPSA_Product class and represents the top level marketing information for the Array System.
Table 4-33 Class: SMX_SAStorageEnclosureLocation (HP_Location) Property name Property implementation Caption Enclosure location Port <m> Box <n>, where <m> is the port and <n> is the box number Description Enclosure location Port <m> Box <n>, where <m> is the port and <n> is the box number Name PhysicalPosition...
Table 4-34 Class: Class: SMX_SATSASPort (HPSA_TSASPort) Property name Property implementation PortType 94 (SAS) HPSA_SAISASPort SMX_SATSASSCSIProtocolEndpoint 4-3-34 SMX_SATSASSCSIProtocolEndpointPort implements the HPSA_TSASSCSIProtocolEndpoint class and represents an access point to storage resources. Table 4-35 Class: SMX_SATSASSCSIProtocolEndpoitPort (HPSA_TSASSCSIProtocolEndpoint) Property name Property implementation ElementName Protocol Endpoint for xxx, where xxx is the value populated in the caption property of the instance of HPSA_TSASPort associated to this instance through the association HPSA_TSASPortTSASSCSIPE...
Table 4-36 Class: Class: SMX_SAISASPort (HPSA_ISASPort) Property name Property implementation OperationalStatus[0] Port status 0 (Unknown) 2 (OK) 6 (Error) EnabledDefault 2 (Enabled EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CreationClassName “SMX_SAISASPort” DeviceID HPSA_PortController.DeviceID>:<port #>, where <HPSA_PortController.DeviceID> is the DeviceID property of the instance of HPSA_PortController associated to this instance through the association HPSA_PortControllerISASPort and <port #>...
Table 4-45 Class: SMX_SASCSIInitiatorTargetLogicalUnitPath (CIM_InitiatorTargetLogicalUnitPath) LogicalUnit SMX_SAStorageExtent State 0 (Unknown) if the path status cannot be ascertained 2 (active) if the path is active and health 5 (path error) if the path has an error condition 3 (passive) path is health but is not active or is the standby path SMX_SAArraySystemRedundancySet (Association) 4-3-45...
Table 4-94 Class: SMX_SAStorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Element SMX_SAStorageEnclosure PhysicalLocation SMX_SAStorageEnclosureLocation Supported indications HP_DeviceIndication: Physical Drive Status Changed 4-4-1 to OK Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication...
Page 92
Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication...
Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation VariableNames Failure Description DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) VariableValues[] FailureDescription short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive.
Page 94
HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-96 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation HP_AlertIndication Summary Physical Drive status is now Error EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-96 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk F/W version string HWLogicalLocation Physical Disk Location string For exmaple, Port:1E Box: 1 Bay 5...
Page 96
HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the array system.
Page 97
HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems...
HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation DeviceModel Physical Disk Model string DeviceControllerLogicalLocation Controller Location For exmaple, SmartArray 642 in Slot 2, Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HP_DeviceIndication: Physical Drive Status...
Page 99
HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-98 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Predictive Failure NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-98 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation HWLogicalLocation Physical Disk Location string For example, Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number VariableNames[]...
Page 101
HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-99 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation AlertingMangedElement WBEM Path of SMX_SAStorageVolume AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array...
Page 102
HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-99 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated.
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Error.
Page 104
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation DeviceOperationalStatus Current OperationalStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: SMX_SAStorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume...
Page 106
SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-101 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of physical drives.
Page 107
SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-101 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect...
HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from non- OK to OK.
Page 109
HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103...
Page 111
HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation ProbableCause 24 (I/O device error)) ProbableCauseDescription Array Controller Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer Array Controller Manufacturer string...
Page 113
HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-104 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array...
Page 114
HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-104 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated.
HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller has detected that redundancy has been lost due to failure or loss of communication with partner controller.
Page 116
HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID...
HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106...
Page 118
HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause 1 (other) ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer...
Page 120
HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-107 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray...
Page 121
HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-107 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Battery status has changed to Not Fully Charged.
Page 123
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel...
Page 125
HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-109 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation HP_AlertIndication Summary Controller Battery Status set to Failed. EventCategory 6 (Primary Storage) ProbableCause 92 (battery failure) ProbableCauseDescription Controller Battery Status Changed to Failed NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-109 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5...
Page 127
HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-110 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation Description Smart Array Controller Cache Status has changed to a status of OK. AlertingMangedElement WBEM path to the SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType...
Page 128
HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-110 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description Smart Array Controller Cache Status is set to a status of Temporarily Disabled.
Page 130
HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-112 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion...
Page 134
HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Storage Enclosure Power Subsystem status has changed to a Non Redundant Status AlertingMangedElement WBEM path of the SMX_SAStorageEnclosureProcessor AlertingElementFormat...
HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
Page 136
HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-114 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to...
HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-114 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
Page 138
HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-115 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Degraded Redundancy.
HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-115 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
Page 140
HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-116 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed from Non-OK to a status of OK.
HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-116 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
Page 142
HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-117 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition.
Page 143
HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-117 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-118 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
Page 145
HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-118 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-119 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed from a status of Non-OK to a status of OK.
Page 147
HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-119 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-120 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to a status of Degraded.
Page 149
HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-120 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-121 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to a status of Failure.
Page 151
HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-121 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
Smart Array View Class Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA’s and the attached devices. The current View Class implementation does not support externally attached Smart Array based MSA devices. For example, MSA500, or MSA20. Class Implementations HPVC_SAController 5-2-1...
Table 5-4 Class: HPVC_SAStorageExtent Property name Property implementation CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageExtent DeviceID HPVC_SAStorageExtent-<model>-<serial number> For example, HPVC_SAStorageExtent- HPDG072BB975-3NP2TCCF000098402P95 SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_StorageExtent BlockSize Block size in bytes NumberOfBlocks Total number of blocks on disk drive Primordial Set to True VMware_StorageExtent HPVC_SAStorageExtent...
SMX_SAS HBA Provider Overview The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. SMX_SASArraySystem 6-1-1 SMX_SASArraySystem represents the top level system. There is one instance per HBA. Table 6-1 Class: SMX_SASArraySystem (CIM_ComputerSystem) Property name...
Table 6-1 Class: SMX_SASArraySystem (CIM_ComputerSystem) Property name Property implementation OtherIdentifyingInfo Controller Serial Number SMX_SASArrayController 6-1-2 SMX_SASArrayController represents the controller. There is one per HBA. Table 6-2 Class: SMX_SASArrayController (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller...
Page 159
Table 6-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description For example, Logical Volume 1 (RAID 1) CIM_ManagedSystemElement Name Concatenation of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 CIM_LogicalElement CIM_EnabledLogicalElement...
Table 6-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation NameFormat 7 (SNVM) SMX_SASStoragevolume Deleteable See HP SAS HBA Profile FaultTolerance See HP SAS HBA Profile OperationalStatus[0] Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data •...
Table 6-4 Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_MediaAccessDevice CIM_DiskDrive SMX_SASDiskDrive DriveConfiguration See HP SAS HBA Profile DriveHasMNPData See HP SAS HBA Profile DriveInterface See HP SAS HBA Profile DrivePlacement See HP SAS HBA Profile DriveRotationalSpeed See HP SAS HBA Profile Description...
Table 6-5 Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] Indicates extended status for the disk drive •...
Table 6-7 Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage SMX_SASDiskPhysicalPackage 6-1-8 SMX_SASDiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. Table 6-8 Class: SMX_SASDiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName...
SMX_SASPortController 6-1-9 SMX_SASPortController represent the HBA in the host system. There is one instance per HBA. Table 6-9 Class: SMX_SASPortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement...
SMX_SASPrimordialPoolNoRaid 6-1-13 SMX_SASPrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes. Table 6-13 Class: SMX_SASPrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial Pool (No Raid) CIM_ManagedSystemElement CIM_LogicalElement...
Table 6-14 Class: SMX_SASStoragePool (CIM_StoragePool) Property name Property implementation Primordial FALSE RemainingManagedSpace TotalManagedSpace Total raw space managed by this pool SMX_SASStoragePool SMX_SASStorageSetting 6-1-15 SMX_SASStorageSetting represents the current raid configuration for a Storage Volume. There is one instance per Storage Volume. Table 6-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name...
Table 6-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation PackageRedundancyMin • 0 (RAID 0) • 1 (RAID 1) SMX_SASStorageSetting SMX_SASSCSIProtocolEndpoint 6-1-16 SMX_SASSCSIProtocolEndpoint represents an access point to storage resources. Table 6-16 Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement...
Table 6-17 Class: SMX_SASSCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Operational status of the controller • 0 (Unknown) • 2 (OK) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement...
Table 6-20 Class: SMX_SASArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Description Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3...
Table 6-21 Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation SMX_SASStorageCapabilities 6-1-22 SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool. Table 6-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name...
Table 6-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation NoSinglePointOfFailure • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) • False—When number of drives = 1 or Pool is NonRAID NoSinglePointOfFailureDefault • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) •...
Table 6-24 Class: SMX_SASDriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <m> Box <n>, where <m> is the name of the port this drive cage is connected and <n> is the Box Number For example, Port IE Box 1 CIM_ManagedSystemElement Name Serial Number of drive cage...
Table 6-26 Class: SMX_SASStorageEnclosure (HP_StorageEnclosure) Property name Property implementation PartNumber N/A—Not available in this implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures). Opaque key Version N/A—Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable)
Table 6-69 Class: SMX_SASDiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASDiskPhysicalPackage PhysicalLocation SMX_SASDiskDriveLocation SMX_SASSCSIProtocolEndpointSCSIProtocolController 6-1-70 (Association) Table 6-70 Class: SMX_SASSCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name Property implementation AvailableSAP SMX_SASSCSIProtocolEndpoint ManagedElement SMX_SASSCSIProtocolController Supported indications SAS HBA status OK 6-2-1 Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation CIM_Indication...
Page 191
Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status OK EventCategory 11 (I/O Adapter) ProbableCause 1 (Other) ProbableCauseDescription HBA Status Changed to OK ProviderVersion...
Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string...
Page 193
Table 6-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status Error EventCategory 11 (I/O Adapter) ProbableCause 2 (Adapter/Card Error) ProbableCauseDescription HBA Status Changed to Error ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
Table 6-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string...
Page 195
Table 6-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive Status is now OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Physical Drive Status Changed to OK ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
Table 6-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
Page 197
Table 6-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation ProviderName HP SAS RecommendedActions Check for failed or removed physical drives. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive status Error...
Table 6-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name...
Page 199
Table 6-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation AlertingMangedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 6-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
Page 201
Table 6-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure. AlertingMangedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown...
Table 6-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “”...
Page 203
Table 6-77 HP_DeviceIndication: Logical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed from non-OK to OK. AlertingMangedElement WBEM Path of Storage Volume AlertingElementFormat...
Table 6-77 HP_DeviceIndication: Logical Drive status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
Page 205
Table 6-78 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check for failed or removed physical drives. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
Table 6-78 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
Page 207
Table 6-79 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation HP_AlertIndication Summary Logical drive degraded state EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Logical Drive State Changed to Degraded ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
Table 6-79 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Enclosure Power Supply status changed to Non 6-2-10 Redundant Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation...
Page 209
Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation NetworkAddresses List of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 32-bit: 69 • For Windows 2003 64-bit: 70 •...
Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to OK 6-2-11 (Redundant) Table 6-81...
Page 211
Table 6-81 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build> NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType •...
Table 6-81 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication...
Page 213
Table 6-82 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation Summary Power supply status Redundant Degraded EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power supply failure) ProbableCauseDescription Redundant Power Supply Degraded ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
Table 6-82 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment...
Page 215
Table 6-83 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation HP_AlertIndication Summary Temperature sensor status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType •...
Table 6-83 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
Page 217
Table 6-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating...
Table 6-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName *...
Page 219
Table 6-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
Table 6-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
Page 221
Table 6-86 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions...
Table 6-86 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
Page 223
Table 6-87 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation Description A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there might be a problem with one or more of the fans. AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath)
Table 6-87 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “”...
Page 225
Table 6-88 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
Page 226
Table 6-88 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
Base Server Overview The SMX Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, Power Supplies, Processor and Memory (Volatile and/or Non-Volatile Storage).
Page 228
Table 7-2 Class: SMX_ComputerSystem Properties Property name Property implementation CIM_ManagedElement Caption Computer system DNS name returned by uname Description Computer system DNS name returned by uname ElementName Computer system DNS name returned by uname CIM_ManagedSystemElement Status Same as OpertionaStatus (0) OperationalStatus OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of...
Page 229
Table 7-2 Class: SMX_ComputerSystem Properties StatusDescriptions StatusDescriptions[0] contains one of the following corresponding to OperationalStatus[0]: • One or more of the subsystems that make up this computer system have an OperationalStatus value of Unknown. • One or more of the subsystems that make up this computer system have an OperationalStatus value of Other.
Page 230
Table 7-2 Class: SMX_ComputerSystem Properties OtherIdentifyingInfo OtherIdentifyingInfo[0]: <GUID_String> where <GUID_String> is the computer system physical GUID string OtherIdentifyingInfo[1]: <MAC_String> where <MAC_String> is the computer system MAC address OtherIdentifyingInfo[2]: <Model_String>:<Serial Number String> where <Model_String> is the computer system model string; and <Serial Number String> is the computer system physical serial number string OtherIdentifyingInfo[3]: <Tag_String>...
Page 231
Table 7-2 Class: SMX_ComputerSystem Properties PrimaryOwnerName Computer system primary owner name string; initialized to not set. PrimaryOwnerContact Computer system primary owner contact string; initialized to not set). PrimaryOwnerPager Computer system primary owner pager string; initialized to not set. SecondaryOwnerContact Computer system secondary owner contact string; initialized to not set.
SMX_ComputerSystemChassis 7-3-2 SMX_ComputerSystemChassis implements the class HP_ComputerSystemChassis to model the physical system chassis. There is only one instance of SMX_ComputerSystemChassis instantiated on a server. Table 7-4 Class: SMX_ComputerSystemChassis Property name Property implementation CIM_PhysicalElement Unique value for instance, for example 1 CreationClassName SMX_ComputerSystemChassis ElementName...
Table 7-4 Class: SMX_ComputerSystemChassis Property name Property implementation VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber If Synergy is enabled, this will contain the logical Serial Number for the system. SMX_ComputerSystemChassis SMX_ComputerSystemPackage 7-3-3 SMX_ComputerSystemPackage implements the class HP_ComputerSystemPackage and associates instances of SMX_ComputerSystem and SMX_ComputerSystemChassis.
Table 7-7 Class: SMX_RunningOS Property name Property implementation Dependent ref: CIM_ComputerSystem SMX_RunningOS SMX_InstalledOS 7-3-6 SMX_InstalledOS implements the class CIM_InstalledOS and associates the SMX_ComputerSystem instance and an SMX_OperatingSystem instance. Table 7-8 Class: SMX_InstalledOS Property name Property implementation CIM_InstalledOS PartComponent ref: CIM_OperatingSystem GroupComponent ref: CIM_ComputerSystem SMX_InstalledOS...
Page 236
The first numeric value in the VersionString MinorVersion The second numeric value in the VersionString RevisionNumber The third numeric value in the Versionstring VersionString Version of SMX, for example, 02.00.00 Manufacturer Hewlett-Packard Classifications[0] 5 (Instrumentation) IsEntity True TargetOSTypes[0] On ESX, 39(VM) On Linux, 36 (Linux)
Table 7-10 Class: SMX_SoftwareIdentity Property name Property implementation SMX_SMXSoftwareIdentity SMX_SMXInstalledSoftwareIdentity 7-3-9 SMX_SMXInstalledSoftwareIdentity implements the class CIM_InstalledSoftwareIdentity and associates the SMX_ComputerSystem instance and an SMX_SMXSoftwareIdentity instance. Table 7-11 Class: SMX_SMXInstalledSoftwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity InstalledSoftware ref: CIM_SoftwareIdentity System ref: CIM_ComputerSystem SMX_SMXInstalledSoftwareIdentity SMX_SystemFirmware 7-3-10...
For example, HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version MinorVersion The firmware minor version VersionString The firmware version Manufacturer Hewlett-Packard Classifications 11 (Bios/FCode) ClassificationDescriptions System Firmware IdentityInfoValue On ProLiant, this will contain: HPQ:<family_code> where <family_code> is the system ROM family code...
SMX_SystemElementFirmwareIdentity 7-3-12 HP_SystemElementFirmwareIdentity implements the class HP_ElementSoftwareIdentity and associates the HP_ComputerSystem instance and SMX_SystemFirmware instances. Table 7-14 Class: SMX_SystemElementFirmwareIdentity Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity UpgradeCondition 3 (Owner Upgradeable) ElementSoftwareStatus The ElementSoftwareStatus array will contain the following if the Antecedent refers to an instance of an Active Firmware: ElementSoftwareStatus[0]: 6 (Installed)
Table 7-15 Provider Indication Common Properties Property name Property implementation HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. for example, 01.05.00 NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType On ESX, 39 (VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system...
Table 7-16 HP_DeviceIndication: WBEM Providers Started Property name Property implementation ProbableCause 1 (Other) ProbableCauseDescription WBEM Providers Started HP_DeviceIndication: WBEM Providers 7-4-2 Informational Test Indication Table 7-17 HP_DeviceIndication: WBEM Providers Informational Test Indication Property name Property implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_AlertIndication Description This is an information test event...
HP_DeviceIndication: WBEM Providers Warning 7-4-3 Test Indication Table 7-18 HP_DeviceIndication: WBEM Providers Warning Test Indication Property name Property implementation EventID ProviderName HP Test RecommendedActions No action is recommended. HP_AlertIndication Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication HP_DeviceIndication: WBEM Providers Critical Test 7-4-4 Indication Table 7-19...
HP_DeviceIndication: ASR Reboot Occurred 7-4-5 Table 7-20 HP_DeviceIndication: ASR Reboot Occurred Property name Property implementation CIM_Indication PerceivedSeverity 5 (Warning) CIM_AlertIndication Description “The system has rebooted from an Automatic Server Recovery (ASR) event.” AlertType 5 (Device Alert) EventID “1” ProviderName “HP Recovery” RecommendedActions “Determine the nature of the ASR event and take corrective action.”...
HP_DeviceIndication: Thermal Reboot Occurred 7-4-6 Table 7-21 HP_DeviceIndication: Thermal Reboot Occurred Property name Property implementation RecommendedActions “Replace any failed or removed fans. Insure the air flow into, out of, and within the system chassis is not obstructed.” HP_AlertIndication Summary “Thermal reboot occurred.” EventCategory 16 (System Power) ProbableCause...
Page 245
HP_DeviceIndication: POST Occurred 7-4-7 Table 7-22 HP_DeviceIndication: POST Occurred Property name Property implementation VariableTypes VariableTypes[0]: 3 (uint8) VariableTypes[1]: 1 (string) VariableValues VariableValues[0]: The POST error code as specified by the System ROM VariableValues[1]: The POST error string as specified by the System ROM Base Server 245...
Overview The following table details these profiles implemented and files installed by this provider. Table 7-1 Overview Implemented Profiles HP CPU Profile (P00106) HP CPU Consolidated Status Profile (P00107) HP CPU Physical Asset Profile (P00108) HP Location Profile (P00124) Namespaces This provider returns instances in the root/hpq namespace.
Page 247
Table 7-2 Class: HP_Processor Properties Property name Property implementation CIM_ManagedElement Caption Processor in ProcessorBaord=a, where a is the slot number Processor in CPUSocket=b on System Mainboard, where b is the socket number Processor in Socket=b on ProcessorBaord=a where a is the slot number and b is the socket number Description <processor brand string>...
Page 248
Table 7-2 Class: HP_Processor Properties Property name Property implementation HealthState 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled)
Table 7-2 Class: HP_Processor Properties Property name Property implementation NumberOfEnabledCores Number of enabled and operational cores for this processor (for example, 1, 2, 4) Stepping Stepping for processor Role Processor Role Unique ID Unique identifier for processor HP_Processor SMX_Processor SMX_ProcessorCapabilities 8-3-2 SMX_ProcessorCapabilities extends the class CIM_ProcessorCapabilities to model the processor capabilities.
Page 250
Table 8-4 Class: SMX_ProcessorCore Property name Property implementation CIM_ManagedElement Caption Processor:p - Core:c, where p is the processor number and c is the core number Description <processor brand string> (x86 Family x Model y Stepping z) (Processor:p - Core:c), where <processor brand string>...
Table 8-4 Class: SMX_ProcessorCore Property name Property implementation CIM_ProcessorCore InstanceID HPQ:SMX_ProcessorCore:Proc:p Core:c, where p is the processor number and c is the core number. CoreEnabledState 2 (Core Enabled) Characteristics For x86 processors: Characteristics[0]: 3 (32-bit Capable) For x64 processors: ○ Characteristics[0]: 3 (32-bit Capable) ○...
Table 8-5 Class: SMX_HardwareThread Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
Page 253
Table 8-6 Class: SMX_CacheMemory Property name Property implementation Caption One of the following: Level x Data Cache, where x is the cache level number Level x Insturction Cache, where x is the cache level number Level x Unified Cache, where x is the cache level number Examples: Level 1 Data Cache...
Table 8-6 Class: SMX_CacheMemory Property name Property implementation CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory DeviceID One of the following: Proc p, Level x <type> Cache, where p is the processor number, x is the cache level number, and <type>...
Table 8-12 Class: SMX_ProcessorCollection Property name Property implementation GroupOperationalStatus GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 5 (Predictive Failure) 6 (Error) 10 (Stopped) The status values of the processors that make up the overall group operational status are contained in GroupOperationalStatus[1-n].
Table 8-13 Class: SMX_HostedProcessorCollection Property name Property implementation SMX_HostedProcessorCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_ProcessorCollection SMX_MemberOfProcessorCollection 8-3-13 SMX_MemberOfProcessorCollection extends the class CIM_MemberOfCollection and associates the SMX_ProcessorCollection instance with an SMX_Processor instance. Table 8-14 Class: SMX_MemberOfProcessorCollection Property name Property implementation CIM_MemberOfCollection SMX_MemberOfProcessorCollection Member ref: SMX_Processor...
Page 260
Table 8-15 Class: SMX_ProcessorChip Properties Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
Table 8-15 Class: SMX_ProcessorChip Properties Property name Property implementation ElementName Processor in ProcessorBoard=a” where a is the slot number Processor in CPUSocket=b on System Mainboard” where b is the socket number Processor in CPUSocket=b on ProcessorBoard=a” where a is the slot number and b is the socket number Manufacturer processor manufacturer string from SMBIOS (for example, Intel or AMD)
SMX_SystemPhysicalProcessor 8-3-16 SMX_SystemPhysicalProcessor extends the class CIM_Container and associates the SMX_ComputerSystemChassis instance with SMX_ProcessorChip instances. Table 8-17 Class: HP_SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor SMX_SystemPhysicalProcessor GroupComponent ref: SMX_ComputerSystemChassis PartComponent ref: SMX_ProcessorChip SMX_ProcessorLocation 8-3-17 SMX_ProcessorLocation implements the class HP_Location which extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
Page 263
Table 8-18 Class: SMX_ProcessorLocation Property name Property implementation ElementName Processor in ProcessorBaord=a, where a is the slot number Processor in CPUSocket=b on System MainBoard, where b is the socket number Processor in CPUSocket=b on ProcessorBoard=a where a is the slot number and b is the socket number CIM_Location Name HPQ:SMX_ProcessorLocation:a, where a is the slot...
Table 8-18 Class: SMX_ProcessorLocation Property name Property implementation LocationInfoDesc If only socket number is available, LocationInfoDesc[0]: 4 (Socket), indicates that the first element of the LocationInformation array contains the socket number If only slot number is available, LocationInfoDesc[0]: 0 (Slot), indicates that the first element of the LocationInformation array contains the slot number If both socket and slot numbers are available, LocationInfoDesc[0]:...
Table 7-20 Provider Indication Common Properties Property name Property implementation IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication...
HP_DeviceIndication: Processor Failed Post 8-4-1 Table 8-21 HP_DeviceIndication: Processor Failed Post Property name Property implementation AlertType 5 (Device Alert) EventID EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replaced the failed processor HP_AlertIndication Summary CPU Failed Power on Self Test (POST) ProbableCause 1 (Other) HP_DeviceIndication: Processor Disabled by BIOS...
System Fan Overview The SMX System Fan provider implements the classes listed to support fans installed in servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles HP Fan Profile 1.0 (P102) HP Location Profile 1.0 (P124) HP Fan Physical Location Profile 1.0 (P115) Namespaces...
SMX_Fan 9-3-1 SMX_Fan is used to model fans on Servers. Please note: fan numbers for existing instances do not change when other fans are added and removed. Table 9-2 Class: SMX_Fan Property name Property implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO and the location.
Table 9-3 Class: SMX_FanCollection Property name Property implementation GroupOperationalStatus[0] Represents the most severe cooling redundancy status and non-fault tolerant fan operational status: 0 (Unknown)—if fan collection status is unknown 2 (OK)—if fans are operating properly 3 (Degraded)—if no SMX_Fan OperationalStatus[0] for all non-fault tolerant fans report 6 (Error) and SMX_FanRedundancy.RedundancyStatus for any cooling redundancy sets report 3 (Degraded...
Table 9-4 Class: SMX_FanRedundancySet Property name Property implementation InstanceID Unique identifier for this cooling redundancy instance CIM_RedundancySet MaxNumberSupported Represents the maximum number of fans supported for this redundancy set MinNumberNeeded Represents the minimum number of fans needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm 0 (Unknown)
SMX_MemberOfFanCollection 9-3-6 SMX_MemberOfFanCollection is used to represent an association between HP_Fan and HP_FanCollection. Table 9-7 Class: SMX_MemberOfCoolingCollection Property name Property implementation Collection References HP_FanCollection Member References HP_Fan SMX_HostedFanCollection 9-3-7 SMX_HostedFanCollection is used to represent an association between HP_FanCollection and the computer system that contains this collection.
Table 9-10 Class: SMX_FanLocation Property name Property implementation Description Description of the fan location including the name displayed by the MP or iLO. For example: The location of the fan Fan 1. Please refer to the fan position CabinetFan=01 printed on the system.
Table 9-12 Class: SMX_FanModule Property name Property implementation Caption Short description of this fan from the name displayed by the MP or iLO and the location. For example: Fan 1 at CabinetFan=01 Description Fan n provides cooling for FanType. StatusDescription where n represents the number of the fan instance, FanType represents the corresponding string value of the FanType enumeration and StatusDescription...
Table 9-13 Class: SMX_SystemPhysicalFan Property name Property implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_FanModule SMX_RealizesFan 9-3-13 The SMX_RealizesFan class implements the HP_RealizesFan class and associates the HP_Fan instance with HP_FanModule instances. Table 9-14 Class: SMX_RealizesFan Property name Property implementation Antecedent References HP_FanModule Dependent References HP_Fan...
Table 9-15 Class: SMX_FanSlot Property name Property implementation ConnectorLayout 6 (Slot) Number Where n represents the number of the fan slot SMX_SystemFanSlot 9-3-15 SMX_SystemFanSlot class implements the HP_SystemFanSlot class and associates the HP_ComputerSystemChassis instance with HP_FanSlot. Table 9-16 Class: SMX_SystemFanSlot Property name Property implementation GroupComponent...
Table 9-18 Class: SMX_FanSpeedSensor Property name Property implementation ElementName Short description of this fan speed sensor from the name displayed by the MP or iLO and the location. For example: Fan speed sensor for Fan 1 at CabinetFan=01 CIM_Managed SystemElement OperationalStatus[0] 2 (OK) –...
Table 9-19 Class: SMX_SystemFanSensor Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_FanSpeedSensor SMX_AssociatedFanSensor 9-3-19 The SMX_AssociatedFanSensor class implements the HP_AssociatedFanSensor class and associates the HP_FanSpeedSensor instance with HP_Fan instances. Table 9-20 Class: SMX_AssociatedFanSensor Property name Property implementation Antecedent References HP_FanSensor Dependent References HP_Fan...
Table 9-21 Provider Indication Common Properties Property name Property implementation OSType On ESX, 39 (VM) On Linux, 36 (Linux) OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> SystemFirmwareVersion Array of firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the...
Table 9-22 HP_DeviceIndication: Fan Removed Property name Property implementation ProbableCause 1 (Other) ProbableCauseDescription Fan Removed HP_DeviceIndication: Fan Inserted 9-4-3 Table 9-23 HP_DeviceIndication: Fan Inserted Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fan has been inserted. (FanCaption), where FanCaption is the SMX_Fan.Caption for the fan that has been inserted AlertingManagedElement...
HP_SensorHardwareIndication: Fan Failed 9-4-4 Table 9-24 HP_SensorHardwareIndication: Fan Failed Property name Property implementation Description A fan has failed. Please check the failed fan and replace if necessary. (FanCaption), where FanCaption is the SMX_Fan.Caption for the fan that has failed AlertingManagedElement WBEM path of the SMX_Fan instance representing the failed fan AlertingElementFormat...
HP_SensorHardwareIndication: Fan Repaired 9-4-5 Table 9-25 HP_SensorHardwareIndication: Fan Repaired Property name Property implementation HP_AlertIndication Summary Fan repaired EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Repaired HP_DeviceIndication: Fan Degraded 9-4-6 The repaired indication is not supported on ProLiant Systems as the fans do not report a degraded status.
HP_DeviceIndication: Fan Redundancy Reduced 9-4-7 Table 9-27 HP_DeviceIndication: Fan Redundancy Reduced Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fault tolerant fan is no longer providing cooling for a cooling redundancy set. (RedundancySetCaption), where RedundancySetCaption represents the SMX_FanRedundancySet.Caption for the redundancy set with reduced redundancy.
HP_DeviceIndication: Fan Redundancy Lost 9-4-8 Table 9-28 HP_DeviceIndication: Fan Redundancy Lost Property name Property implementation AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName HP Cooling RecommendedActions Check the fan configuration and check the status of the cooling redundancy.
HP_DeviceIndication: Fan Redundancy Restored 9-4-9 Table 9-29 HP_DeviceIndication: Fan Redundancy Restored Property name Property implementation RecommendedActions No action is recommended. HP_AlertIndication Summary Cooling redundancy has been restored EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Cooling Redundancy has been Restored HP_DeviceIndication: Fan Redundancy Failed 9-4-10 The redundancy failed indication is not supported on ProLiant systems since redundancy...
Page 287
HP_DeviceIndication: Fan Redundancy Failed 9-4-10 The redundancy failed indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Table 9-30 HP_DeviceIndication: Fan Redundancy Failed Property name Property implementation EventCategory 23 (System Cooling) ProbableCause 88 (Loss of Redundancy)
System Power Supply Overview 10-1 The SMX Power Supply provider implements the HP Power Supply profile to model power supplies in systems. The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles HP Power Supply Profile 1.0 (P103) HP Location Profile 1.0 (P124) HP Power Supply Physical Asset Profile 1.0 (P116)
• SMX_SystemPowerMeter • SMX_AssociatedPowerMeter SMX_PowerSupply 10-3-1 SMX_PowerSupply is used to model power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 10-2 Class: HP_PowerSupply Property name Property implementation CIM_ManagedElement Caption...
Table 10-2 Class: HP_PowerSupply Property name Property implementation Name Name of this power supply from the name displayed by the MP or iLO and its location. For example, Power Supply 1 at PowerSupplySlot=2 Power supply 1a at PowerSupplySlot=2 TimeOfLastStateChange Time that state last changed for power supply.
Table 10-3 Class: SMX_PowerCollection Property name Property implementation HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) —If power collection status is unknown 2 (OK) —If power supplies are operating properly 3 (Degraded) —If no SMX_PowerSupply.OperationalStatus[0] for all non- fault tolerant power supplies report 6 (Error) and...
Table 10-4 Class: SMX_PowerRedundancySet Property name Property implementation CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance CIM_RedundancySet MaxNumberSupported The maximum number of power supplies supported for this redundancy set MinNumberNeeded The minimum number of power supplies needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm...
SMX_HostedPowerRedundancySet 10-3-5 SMX_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the computer system that contains this redundancy set. Table 10-6 Class: SMX_HostedPowerRedundancySet Property name Property implementation OwningElement References HP_ComputerSystem OwnedElement References HP_PowerRedundancySet SMX_MemberOfPowerCollection 10-3-6 SMX_MemberOfPowerCollection is used to represent an association between HP_PowerSupply and HP_PowerCollection.
Table 10-9 Class: SMX_PowerSupplyLocation Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerSupply SMX_PowerSupplyLocation 10-3-9 SMX_Location is used to model power supply locations on servers. Table 10-10 Class: SMX_PowerSupplyLocation Property name Property implementation CIM_ManagedElement Caption Name of this power supply from the name displayed by the MP or iLO and its location.
Page 295
Table 10-11 Class: SMX_PowerSupplyElementLocation Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location System Power Supply 295...
SMX_PowerSupplyModule 10-3-11 SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 10-12 Class: SMX_PowerSupplyModule Property name Property implementation CIM_ManagedElement Caption Short description of this power supply from the name displayed by the MP or iLO and its location.
Table 10-12 Class: SMX_PowerSupplyModule Property name Property implementation Unique identifier for this power supply instance PartNumber Part number of the power supply CIM_PhysicalPackage RemovalConditions 0(Unknown) 3 (Removable when off) 4 (Removable when on or off) Package Type 6 (PowerSupply) SMX_SystemPhysicalPowerSupply 10-3-12 SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association the HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
Table 10-15 Class: SMX_PowerSupplySlot Property name Property implementation Description Description of the power supply slot, For example: PowerSupplySlot=2 ElementName Name of the power supply slot, For example: PowerSupplySlot=2 CIM_Managed SystemElement OperationalStatus[0] 2 (OK) – if power supply slot is operating properly StatusDescriptions[0] Power Supply slot is operating properly –...
OperationalStatus. For example: OK; HealthState 5 (OK) Name Power controller firmware CIM_LogicalElement CIM_SoftwareIdentity InstanceID Opaque key Classifications Hewlett-Packard Company ClassificiationsDescriptions 10 (Firmware) IsEntity Power controller firmware The firmware version string VersionString The firmware major version MajorVersion System Power Supply 299...
Table 10-18 Class: SMX_PowerControllerFirmware Property name Property implementation The firmware minor version MinorVersion The firmware revision number RevisionNumber SMX_PowerControllerElementFirmwareIdentity 10-3-18 The SMX_PowerControllerElementFirmwareIdentity class associates the SMX_ComputerSystem instance with the SMX_PowerControllerFirmware. Table 10-19 Class: SMX_PowerControllerElementFirmwareIdentity Property name Property implementation Antecedent References HP_PowerControllerFirmware Dependent References HP_ComputerSystem UpgradeCondition...
Page 301
Table 10-21 Class: SMX_PowerMeter Property name Property implementation Caption Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO and location. For example: Power utilization sensor for Power Supply 1 at PowerSupplySlot=1 Description Description of this power utilization sensor including the Caption and StatusDescriptions.
Table 10-21 Class: SMX_PowerMeter Property name Property implementation SensorType 13 (Power Consumption) CurrentState “Normal” PossibleStates Array may contain the following value: PossibleStates[0] = ”Normal” CIM_NumericSensor CurrentReading Current reading of the power meter BaseUnits 7 (Watts) RateUnits 0 (None) UnitModifier HP_PowerMeter SMX_SystemPowerMeter 10-3-21 The SMX_SystemPowerMeter class associates the SMX_ComputerSystem instance with the...
Table 10-23 Provider Indication Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName...
Table 10-24 HP_DeviceIdentification: Power Supply Removed Property name Property implementation CIM_AlertIndication Description A power supply has been removed. (Power Supply), where Power Supply is the system power supply that was removed AlertingManagedElement WBEM path of the SMX_WinPowerSupply instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID...
HP_DeviceIndication: Power Supply Inserted 10-4-3 Table 10-25 HP_DeviceIndication: Power Supply Inserted Property name Property implementation Power Supply Summary inserted EventCategory 16 (System Power) ProbableCause 1 (Other) ProbableCauseDescription Power Supply has been Inserted HP_DeviceIndication: Power Supply Failed 10-4-4 Table 10-26 HP_DeviceIndication: Power Supply Failed Property name Property implementation CIM_Indication...
HP_DeviceIndication: Power Supply Degraded 10-4-5 Table 10-27 HP_DeviceIndication: Power Supply Degraded Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A power supply has failed. (PowerSupplyCaption) where PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has degraded AlertingMangedElement WBEM path of the SMX_PowerSupply instance representing the degraded power supply AlertingElementFormat...
HP_Device Indication: Power Supply Repaired 10-4-6 Table 10-28 HP_Device Indication: Power Supply Repaired Property name Property implementation AlertType 5 (Device Alert) EventID ProviderName HP Power RecommendedActions No action is recommended. HP_AlertIndication Summary PowerSupplyCaption has been repaired, where PowerSupplyCaption is the HP_WinPowerSupply. Caption for the power supply that has been repaired.
10-4-7 HP_Device Indication: Power Supply Redundancy Reduced Table 10-29 HP_DeviceIndication: Power Supply Redundancy Reduced Property name Property implementation ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Power Redundancy has been Reduced HP_DeviceIndication: Power Supply Redundancy 10-4-8 Lost Table 10-30 HP_DeviceIndication: Power Supply Redundancy Lost Property name Property implementation CIM_Indication...
HP_DeviceIndication: Power Supply Redundancy Failed 10-4-9 This indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Table 10-31 HP_DeviceIndication: Power SupplyRedundancy Failed Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description...
Page 310
Table 10-32 HP_DeviceIndication: Power Supply Redundancy Restored Property name Property implementation Description Power redundancy for the system has been restored. (RedundancySetCaption), where RedundancySetCaption is SMX_PowerRedundancySet.Caption of the redundancy set the power redundancy set with restored redundancy AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the power redundancy set with restored redundancy AlertingElementFormat...
SMX Profile registration provider Overview 11-1 The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles • HP Profile Registration Profile (POO100) Namespaces 11-2 This provider returns instances in the root/hpq namespace. Class implementations 11-3 The classes below describe registration of HP profiles.
Table 11-2 Class: SMX_RegisteredProfile Property name Property implementation InstanceID HPQ:n where n is a unique number OtherRegisteredOrganization NULL for DMTF profiles None for SNIA SMI-S storage profiles RegisteredName Table 3 lists the property values for this class RegisteredOrganization 2 (DMTF) for DMTF profiles 11 (SNIA) for SNIA SMI-S storage profiles RegisteredVersion Table 3 lists the property values for this class...
Page 313
This is the list of all possible SNIA profiles. Some implementations only support a subset of these profiles, so only those subsets are reported. Table 10-4 Property values of SMX_RegisteredProfile for SNIA Profiles Registered Name Registered version Caption/Description/ElementName SNIA Block Services Block Services 1.3.0 Profile...
Page 314
RegisteredName RegisteredVersion Caption/Description/ElementName HP Fan Physical Asset 1.0.0 HP Fan Physical Asset Profile HP Power Supply Physical 1.0.0 HP Power Supply Physical Asset Profile Asset HP CPU Consolidated 1.0.0 HP CPU Consolidated Status Profile Status HP Sensors 1.0.0 HP Sensors Profile HP Record Log 1.0.0b HP Record Log Profile...
Page 315
Table 11-5 Class: SMX_RegisteredProfile Property name Property implementation RegisteredName See Table 5 RegisteredOrganization 1 (Other) for HP WBEM TC profiles RegisteredVersion Table 3 lists the property values for this class SMX_RegisteredProfile Table 10-6 Property Values of SMX_RegisteredProfile for HP WBEM TC Profiles Registered Name Registerred version Caption/Description/ElementName...
SMX_ExtendsProfile 11-3-2 SMX_ExtendsProfile extends the class CIM_Dependency and associates an extension profile registration and the parent profile it extends. Table 11-7 Class: SMX_ExtendsProfile Property name Property implementation CIM_Dependency HP_ExtendsProfile Antecedent ref: CIM_RegisteredProfile (extended) * Dependent ref: HP_RegisteredProfile (extends) * SMX_ReferencedProfile 11-3-3 SMX_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in the root\Interop namespace.
System Temperature Sensor Overview 12-1 This provider implements the HP Sensor Profile to model temperature sensors in ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 11-1 Overview Implemented Profiles HP Sensor Profile 1.0 Use cases 12-2 See HP Sensor Profile for Use Cases.
Page 319
Table 11-2 Class: SMX_NumericSensor Property name Property implementation ElementName Temperature Sensor <sensorID>” where <sensorID> is name displayed by MP or iLO. For example: Temperature Sensor Temp 1 CIM_ManagedSystemElement OperationalStatus[0] 2 (OK)—if temperature reported by the sensor is within normal operating range; 2 (OK)—if temperature reported by the sensor has exceeded its non-critical threshold and has set fans to full speed;...
Table 11-2 Class: SMX_NumericSensor Property name Property implementation PossibleStates Array can contain any of the following values: PossibleStates[0] = Normal PossibleStates[1] = Critical CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) RateUnits 0 (None) UnitModifier SupportedThresholds SupportedThresholds[0] = 1 (UpperThresholdNotCritical) if the system will set fans to full speed if the threshold is crossed SupportedThresholds[0] = 3 (UpperThresholdCritical)
Table 11-3 Class: SMX_SensorCollection Property name Property implementation Caption Temperature Sensor Collection Description This is a collection of temperature sensors. GroupStatusDescription., where GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property ElementName Temperature Sensor Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this sensor collection instance HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Represents the most severe sensor group operational...
SMX_HostedSensorCollection 12-2-5 SMX_HostedSensorCollection implements HP_HostedSensorCollection and is used to represent an association between SMX_SensorCollection and the computer system that contains the collection. Table 11-5 Class: SMX_HostedSensorCollection Property name Property implementation Antecedent References SMX_ComputerSystem Dependent References SMX_SensorCollection SMX_SystemSensor 12-2-6 SMX_SystemSensor implements HP_SystemSensor and is used to represent an association between SMX_NumericSensor and the computer system that contains the sensor.
Page 323
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName System Temperature RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
Page 324
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation VariableValues SMX_NumericSensor UpperThresholdNonCritical, UpperThresholdCritical, or UpperThresholdFatal property value that is set for the temperature sensor detecting the exceeded threshold ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
Page 325
Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation ProviderName HP Temperature RecommendedActions No action is recommended. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.CreationClassName HP_AlertIndication Threshold exceeded condition recovery Summary EventCategory 23 (System Cooling) ProbableCause 52 (Threshold Crossed) ProbableCauseDescription Threshold Exceeded Condition has Recovered ProviderVersion 2.2.0.0...
Page 326
Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment System Temperature Sensor 326...
System memory Overview 13-1 This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in ProLiant systems. See HP Advanced Memory Protection Technologies (TC060104TB) and product documentation for your ProLiant Server (available at http://www.hp.com). The following table details the profiles implemented and files installed by this provider.
• SMX_MemoryCollection • SMX_HostedMemoryCollection • SMX_MemberOfMemoryCollection • SMX_MemberOfMemoryRedundancySet • SMX_HostedMemoryRedundancySet • SMX_SystemMemoryModuleSlot • SMX_SystemMemoryBoardSlot SMX_Memory 13-2-1 The class SMX_Memory represents logical memory on ProLiant Servers. There is one instance of this class. Table 13-2 Class: SMX_Memory Property name Property implementation CIM_ManagedElement Caption System Memory...
Table 13-3 Class: SMX_SystemMemory Property name Property implementation HP_SystemMemory GroupComponent ref: SMX_ComputerSystem PartComponent ref: SMX_Memory SMX_SystemMemory SMX_MemoryModule 13-2-3 The class SMX_MemoryModule represents a physical memory module on ProLiant Servers. There is an instance of this class for each memory module present in the system. Empty memory module sockets will not be instantiated.
Page 331
Table 13-4 Class: SMX_MemoryModule Property name Property implementation HealthState Enumerator indicating the memory module health state: 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 5 (OK), when OperationalStatus[0] = 2 (OK) 10 (Degraded/Warning), when OperationalStatus[0] = 3 (Degraded) Name Physical Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory...
Page 332
Table 13-4 Class: SMX_MemoryModule Property name Property implementation ElementName Physical Memory Module Socket=y on MemoryBoard= x, where: x is the board/cartridge number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module Socket=y on ProcessorBoard =x, where: x the processor board number where the memory...
Table 13-4 Class: SMX_MemoryModule Property name Property implementation PositionInRow Position of memory module in a row. This property is conditional, it is populated if the data is available. FormFactor Enumerator indicating the form factor of the memory module. See the MOF file for details. BankLabel String identifying the physically labeled bank where the memory is located.
Page 334
Table 13-6 Class: SMX_MemoryBoard Property name Property implementation Caption Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x , where x is the processor board/cartridge number where the memory board is located. CIM_ManagedSystemElement OperationalStatus Enumerator indicating the memory board operational...
Page 335
Table 13-6 Class: SMX_MemoryBoard Property name Property implementation ElementName Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x , where x is the processor board/cartridge number where the memory board is located. CIM_PhysicalPackage RemovalConditions Removal conditions of the memory board:...
Table 13-7 Memory Board Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory board has a configuration 3 (Degraded) 3 (Degraded) error, for example, there is a Degraded Memory board status: Configuration problem with the board release error latch (unlock error) or there is an improper configuration of memory modules on the board.
Page 337
Table 13-9 Class: SMX_MemoryModuleSlot Property name Property implementation Caption Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located...
Table 13-9 Class: SMX_MemoryModuleSlot Property name Property implementation ElementName Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located...
Page 339
Table 13-10 Class: SMX_MemoryBoardSlot Property name Property implementation Caption Memory Board Slot MemoryBooard=x, where x is the board/cartridge number where the memory board is located. Memory Board Slot ProcessorBoard=x, where x is the processor board/cartridge number where the memory board is located. CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK)
SMX_MemoryModuleInSlot 13-2-8 The class SMX_MemoryModuleInSlot represents the association between an SMX_MemoryModule and the SMX_MemoryModuleSlot where it resides. Table 13-11 Class: SMX_MemoryModuleInSlot Property name Property implementation CIM_ElementInConnector HP_ MemoryModuleInSlot SMX_MemoryModuleInSlot Antecedent ref: SMX_MemoryModuleSlot Dependent ref: SMX_MemoryModule SMX_MemoryBoardInSlot 13-2-9 The class SMX_MemoryBoardInSlot represents the association between an SMX_MemoryBoard and the SMX_MemoryBoardSlot where it resides.
SMX_MemoryModuleSlotLocation 13-2-11 The class SMX_MemoryModuleSlotLocation extends the CIM_Location class and represents memory module slot locations on ProLiant Servers. There will be an instance of this class for each memory module slot in the system (whether the slot is occupied or not). Table 13-14 Class: SMX_ MemoryModuleSlotLocation Property name...
Table 13-14 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation Name HPQ:SMX_MemoryModuleSlotLocation:x-y, where: x is the board/cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located PhysicalPosition Opaque key. Example for memory socket number 2 on cpu/board/cartridge number 1: FF-FF-FF-FF-01-02-FF-79...
Table 13-15 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation Description Memory Board Slot Location MemoryBoard=x, where: x is the board/cartridge number where the memory board slot is located Memory Board Slot Location ProcessorBoard= x, where: x is the processor board/cartridge number where the memory board slot is located ElementName Memory Board Slot Location MemoryBoard=x, where:...
Table 13-16 Class: SMX_MemoryModuleSlotElementLocation Properties Property implementation CIM_ElementLocation HP_ElementLocation SMX_MemoryModuleSlotElementLocation Element ref: SMX_MemoryModuleSlot PhysicalLocation ref: SMX_MemoryModuleSlotLocation SMX_MemoryBoardSlotElementLocation 13-2-14 The class SMX_MemoryBoardSlotElementLocation extends the class CIM_ElementLocation and is used to associate a memory board slot (SMX_MemoryBoardSlot) with its corresponding location (SMX_MemoryBoardSlotLocation). There will be an instance of this class for each memory board slot in the system (whether the slot is occupied or not).
SMX_SystemMemoryBoard 13-2-16 The class SMX_SystemMemoryBoard represents an association between SMX_MemoryBoard and SMX_ComputerSystemChassis. There will be an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). Table 13-19 Class: SMX_SystemMemoryBoard Properties Property implementation CIM_Container HP_SystemMemoryBoard...
Page 346
Table 13-20 Class: SMX_MemoryRedundancySet Property name Property implementation OtherTypeOfSet OtherTypeOfSet[0] contains the type of redundancy when the property TypeOfSet[0] = 1 (Other). In this case, the property will contain the value Advanced ECC or Lockstep, otherwise the property is not populated. LoadBalanceAlgorithm 2 (No Load Balancing) RedundancyStatus...
Table 13-20 Class: SMX_MemoryRedundancySet Property name Property implementation TargetConfiguration The desired or targeted mode of the Advanced Memory Protection system. TargetConfiguration is one of the following: • Advanced ECC, when the system is configured for Advanced ECC mode • RAID, when the system is configured for RAID (XOR) mode •...
Table 13-21 Class: SMX_MemoryCollection Property name Property implementation GroupOperationalStatus Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the worst-of algorithm for physical memory boards...
Table 13-23 Class: SMX_HostedMemoryCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_HostedMemoryCollection SMX_HostedMemoryCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_MemoryCollection SMX_MemberOfMemoryCollection 13-2-20 The class SMX_ MemberOfMemoryCollection represents an association between SMX_MemoryCollection and SMX_MemoryModule or SMX_MemoryBoard. Table 13-24 Class: SMX_MemberOfMemoryCollection Property name Property implementation CIM_MemberOfCollection HP_MemberOfMemoryCollection...
SMX_HostedMemoryRedundancySet 13-2-22 The class SMX_HostedMemoryRedundancySet represents an association between SMX_MemoryRedundancySet and the computer system that contains this redundancy set. Table 13-26 Class: SMX_HostedMemoryRedundancySet Property name Property implementation CIM_OwningCollectionElement HP_HostedMemoryRedundancySet SMX_HostedMemoryRedundancySet OwningElement ref: SMX_ComputerSystem OwnedElement ref: SMX_MemoryRedundancySet SMX_SystemMemoryModuleSlot 13-2-23 Note: This class is currently NOT implemented. The class SMX_SystemMemoryModuleSlot represents an association between SMX_MemoryModuleSlot and SMX_ComputerSystemChassis.
Table 13-28 Class: SMX_SystemMemoryBoardSlot Properties Property implementation SMX_SystemMemoryBoardSlot GroupComponent ref: SMX_ComputerSystemChassis PartComponent ref: SMX_MemoryBoardSlot Supported indications 13-3 The following table describes the properties that are common to all of the SMX Memory Provider indications that are implemented for server platforms, where available: Table 13-29 Provider Indication Common Properties Property name...
Page 352
Table 13-29 Provider Indication Common Properties Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication The following tables describe the SMX Memory Provider indications that are implemented for server platforms where available: Table 13-30 SMX_MemoryIndication: Memory Module Predictive Failure Property name Property implementation CIM_Indication...
Page 353
Table 13-31 SMX_MemoryIndication: Memory Board Error Property name Property implementation Description A memory board has an error. (MemoryBoardCaption) where MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board. Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation AlertingManagedElement WBEM Path of SMX_MemoryBoard instance representing the memory board AlertingElementFormat 2 (CIMObjectPath)
Page 354
Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation RecommendedActions Check the Advanced Memory Protection configuration and replace the memor board and memory modules as necessary.” HP_AlertIndication Summary Advanced Memory Protection degraded EventCategory 3 (Memory) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Advanced Memory Protection Degraded CIM_Indication...
Blade System Lite Overview 14-1 The following profiles are implemented, and the following files are installed by this provider. Table 14-1 Overview Implemented Profiles • HP Blade System Lite Profile 2.0.3 Namespaces 14-2 This provider returns instances in the root/hpq namespace. Class implementations 14-3 The following classes reside in the local host OS CIMOM on each individual blade system and...
Page 356
Table 14-2 Class: SMX_BladeEnclosureCS Property name Property implementation OperationalStatus • 0 (Unknown), enclosure status: Unknown • 2 (OK), enclosure status: OK • 3 (Degraded), enclosure status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown •...
Table 14-2 Class: SMX_BladeEnclosureCS Property name Property implementation ManagementIPAddress The enclosure’s management IP address ManagementURL The URL of the enclosure’s management web-based user interface ProductID The blade enclosure product name (model) string SerialNumber The blade enclusure serial number string RackName The name of the rack string RackUUID The UUID of the rack string...
Table 14-3 Class: SMX_BladeEnclosureCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded • Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection...
SMX_BladeEnclosureGroupHostedCollection 14-3-5 SMX_BladeEnclosureGroupHostedCollection extends the class HP_GroupHostedCollection and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following properties are implemented. Table 14-6 Class: SMX_BladeEnclosureGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_BladeEnclosureGroupHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_BladeEnclosureCollection CIM_SoftwareIdentity...
VersionString String indicating the blade enclosure firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue An array in which first element contains the path of the...
Table 14-9 Class: SMX_BladeEnclosureInstalledFWIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System ref: HP_BladeEnclosureCS InstalledSoftware ref: HP_BladeEnclosureFW SMX_BladeCSLocation 14-3-9 SMX_BladeCSLocation is used to model the server blade location within an enclosure. Table 14-10 Class: SMX_BladeCSLocation Property name Property implementation CIM_ManagedElement Caption Blade Computer System Bay Location n, where n represents the blade bay slot position printed on the enclosure labeling...
Table 14-11 Class: HP_ElementLocation Property name Property implementation Element References CIM_ComputerSystem PhysicalLocation References CIM_Location Supported indications 14-4 There are no indications specific to the blade system implementation. Blade System Lite 362...
FC HBA Overview 15-1 This provider implements the HP FC HBA Profile which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports.
Table 15-3 Class: SMX_FCHBAFCPort Property name Property implementation UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress PortWWN PortNumber Port number SupportedMaximumTransmissionUnit Port maximum frame size SMX_FCHBAPortController 15-3-3 SMX_FCHBAPortController is a logical device corresponding to a hardware network port controller. Table 15-4 Class: SMX_FCHBAPortController Property name...
SMX_FCHBAFCPortStatsitics represents statistics for a Fibre Channel port. In the following table HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure. This information comes directly for the HBA and is not altered. Table 15-5 Class: SMX_FCHBAFCPortStatistics Property name Property implementation CIM_ManagedElement ElementName Product name...
Table 15-6 Class: SMX_FCHBALogicalPortGroup Property name Property implementation Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat SMX_FCHBAPhysicalPackage 15-3-6 SMX_FCHBAPhysicalPackage class represents the physical elements of the associated Fibre Channel port controller.
Table 15-7 Class: SMX_FCHBAPhysicalPackage Property name Property implementation Version Board Version or N/A when not available CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_FCHBAProduct 15-3-7 SMX_FCHBAProduct is used to aggregate physical element of the FC HBA. In the following table HBAAPI_ADAPTERATTRIBUTES prefix refers to the HBA API HBA_ADAPTERATTRIBUTES structure. This information comes directly for the HBA and is not altered.
Table 15-9 Class: SMX_FCHBASoftwareIdentityDrv Property name Property implementation CIM_SoftwareIdentity ClassificationDescriptions FC HBA Driver Classifications 2 (Driver) InstanceID HPQ:NodeWWN:<instanceNum> where <instanceNum> is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString File version of the Driver SMX_FCHBAFirmwareIdentityFW 15-3-9 SMX_FCHBA_FirmwareIdentityFW represents adapter firmware associated with the Fibre Channel port controller.
SMX_FCHBAFirmwareIdentityBIOS represents adapter BIOS associated with the Fibre Channel port controller. Table 15-11 Class: SMX_FCHBA_FirmwareIdentityBIOS Property name Property implementation CIM_ManagedElement Caption FC HBA Option ROM Description FC HBA Option ROM detail for Model Name, where product name is the model name of the HBA. ElementName FC HBA Option ROM CIM_ManagedSystemElement...
Table 15-14 Class: SMX_FCHBAComputerSystemPortController Property name Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent ref:SMX_FCHBAComputerSystem PartComponent ref:SMX_FCHBAPortController SMX_FCHBAComputerSystemLogicalPortGroup 15-3-14 SMX_FCHBAComputerSystemLogicalPortGroup is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBALogicalPortGroup. Table 15-15 Class: SMX_FCHBAComputerSystemLogicalPortGroup Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection SMX_FCHBAComputerSystemLogicalPortGroup Antecedent ref:SMX_FCHBAComputerSystem Dependent...
SMX_FCHBAFCPortFCPortStatistics is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics. Table 15-17 Class: SMX_FCHBAFCPortFCPortStatistics Property name Property implementation CIM_ElementStatisticalData SMX_FCHBAFCPortFCPortStatistics ManagedElement ref:SMX_FCHBAFCPort Stats ref:SMX_FCHBAFCPortStatistics SMX_FCHBAFCPortLogicalPortGroup 15-3-17 SMX_FCHBAFCPortLogicalPortGroup is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBALogicalPortGroup. Table 15-18 Class: SMX_FCHBA_FCPortLogicalPortGroup Property name Property implementation...
SMX_FCHBAPhysicalPackagePortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBA_PhysicalPackage. Table 15-20 Class: SMX_FCHBA_PhysicalPackagePortController Property name Property implementation CIM_Dependency CIM_Realizes SMX_FCHBA_PhysicalPackagePortController Antecedent ref:SMX_FCHBAPhysicalPackage Dependent ref:SMX_FCHBAPortController SMX_FCHBASoftwareIdentityDrvPortController 15-3-20 SMX_FCHBASoftwareIdentityDrvPortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBASoftwareIdentityDrv. Table 15-21 Class: SMX_FCHBASoftwareIdentityDrvPortController Property name Property implementation...
SMX_FCHBAPortControllerFirmwareIdentityBIOS 15-3-22 SMX_FCHBAPortControllerFirmwareIdentityBIOS is used to represent an association between SMX_FCHBAPortController and SMX_FCHBA_FirmwareIdentityBIOS. Table 15-23 Class: SMX_FCHBAPortControllerFirmwareIdentityBIOS Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBAPortControllerFirmwareIdentityBIOS Antecedent ref:SMX_FCHBAFirmwareIdentityBIOS Dependent ref:SMX_HPFCHBAPortController SMX_FCHBAProductPhysicalComponent 15-3-23 SMX_FCHBAProductPhysicalComponent is used to represent an association between SMX_FCHBA_Product and SMX_FCHBAPhysicalPackage. Table 15-24 Class:SMX_FCHBAProductPhysicalComponent Property name...
Table 15-25 Class:SMX_FCHBASystemPackaging Property name Property implementation Dependent ref:SMX_ FCHBAComputerSystem SMX_FCHBAGroupHostedCollection 15-3-25 SMX_FCHBAGroupHostedCollection is used to represent an association between SMX_ComputerSystem and SMX_FCHBAGroupSystemSpecificCollection. Table 15-26 Class: SMX_FCHBAGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection SMX_FCHBA_GroupHostedCollection Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_FCHBAGroupSystemSpecificCollection SMX_FCHBAFCPortGroupSystemSpecific 15-3-26 SMX_FCHBAFCPortGroupSystemSpecific is used to represent an association between...
Table 15-28 Class: SMX_FCHBALocation Property name Property implementation CIM_ManagedElement CIM_Location Name NodeWWN: SerialNumber:<instanceNum> Where <instanceNum> is the port controller instance number for the same adapter. HP_Location ElementLocationTag slot number ElementLocationTagDesc 1 (slot) PhysicalPosition Location—PCI Slot x where x is the PCI slot number or PCI Mezzanine=x where x is the Mezzanine slot number SMX_FCHBAPhysicalElementLocation...
Table 15-31 Class: SMX_FCHBASCSIProtocolEndpoint Property name Property implementation SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint ProtocolFType 57 (HIPPI Interface) CIM_SCSIProtocolEndpoint ConnectionType 2 (fibre channel) Role 2 (initiator) SMX_FCHBAComputerSystemSCSIProtocolController 15-3-31 SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolController. Table 15-32 Class: SMX_FCHBAComputerSystemSCSIProtocolController Property name Property implementation...
SMX_FCHBASCSIProtocolControllerFCPort 15-3-33 SMX_FCHBASCSIProtocolControllerFCPort is used to represent an association between SMX_FCHBASCSIProtocolController and SMX_FCHBAFCPort Table 15-34 Class: SMX_FCHBAFCPortSCSIProtocolControllerFCPort Property name Property implementation CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerFCPort SMX_FCHBASCSIProtocolControllerFCPort Antecendent ref:SMX_FCHBASCSIProtocolController Dependent ref:SMX_FCHBAFCPort SMX_FCHBASystemServiceAccessPoint 15-3-34 SMX_FCHBASystremServiceAccessPoint is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolEndpoint. Table 15-35 Class: SMX_ FCHBASystremServiceAccessPoint Property name...
Management Processor Lite Overview 16-1 The profiles are implemented, and the following files are installed by this provider. Table 16-1 Overview Implemented Profiles • HP Management Processor (MP) Lite Profile 2.0.1 Namespaces 16-2 This provider returns instances in the root/hpq namespace. Class implementations 16-3 The following classes are implemented for HP server platforms where available.
Page 383
Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation Description Description of the Management Processor, including the product name. For example: HP Management Processor - <product name> where <product name> is the name of the MP product (same as the product name in property ElementName) Examples: “HP Management Processor –...
Page 384
Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation OperationalStatus Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor (MP) Lite Profile for specific descriptions of when each value is populated). • OperationalStatus[0] contains MP operational status: ○...
Page 385
Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation HealthState • 0 (Unknown), when OperationalStatus[0]=0 (Unknown), or when software interface fails • 5 (OK), normal operation • 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) • 20 (Major failure), when OperationalStatus[0]=6 (Error) Note: When a Management processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
Page 386
Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation ControllerType Enumerator indicating the model or type of management processor (see the HPWmiMgmtProcLite.mof file). • 0 (Unknown) • 1 (Other) • 2 (PCI Board-Remote Insight Lights Out Edition II (RILOE II)) • 3 (Embedded Integrated Lights Out Controller (iLO)) •...
Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation ActiveLicense The currently active iLO license type: • 0 (Unknown) • 1 (None) • 2 (iLO Advanced) • 3 (iLO Light) • 4 (iLO Advanced for BladeSystem) • 5 (iLO Standard for BladeSystem) LicenseKey Management Processor License Key HostName...
Page 388
VersionString String indicating the MP firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware IdentityInfoValue An array in which first element contains the path of the...
SMX_MPCollection 16-3-3 SMX_MPCollection implements the class HP_MPCollection, and represents the collection of all management processor controller systems in a computer system, and forwards group operational status. The following properties are implemented. Table 16-4 Class: SMX_MPCollection Property name Property implementation CIM_ManagedElement Description HP Management Processor Collection ElementName...
Table 16-5 Class: SMX_MPHHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_MPHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_MPCollection SMX_MPComponentCS 16-3-5 SMX_MPComponentCS implements the class HP_MPComponentCS, and associates a management processor subsystem to the scoping computer system that contains it. The following properties are implemented.
Table 16-7 Class: SMX_MPMemberOfCollection Property name Property implementation Included Writeable boolean property indicating if the management processor instance referenced by Member will contribute status to the HP_MPCollection. • TRUE—Include member status in collection status • FALSE—Do not include member status in collection status Collection ref: HP_MPCollection...
Table 16-9 Class: SMX_MPInstalledFirmwareIdentity Property name Property implementation InstalledSoftware ref: HP_MPFirmware Supported indications 16-4 There are no indications specific to the management processor implementation. Management Processor Lite 392...
IML Record Log Overview 17-1 This provider supports the Integrated management Log (IML) on ProLiant systems. The following table details the profiles implemented and files installed by this provider. Table 16-1 Overview Implemented Profiles HP Record Log Profile 1.0 Namespaces 17-2 The provider returns instances in the root/hpq namespace.
Page 394
Table 16-2 Class: SMX_IMLRecordLog Property name Property implementation OperationalStatus OperationStatus[0] indicates the highest severity of IML log entries and will contain one of the following: 2 (OK)— only informational or repaired events exist in the IML log; 3 (Degraded)— at least one degraded event exists in the IML log;...
Table 176-3 Implemented Methods for SMX_IMLRecordLog Class Method Name Method Implementation ClearLog Refer to HP Record Log profile (P00109) RepairAll Refer to HP Record Log profile (P00109) SMX_IMLLogEntry 17-2-3 SMX_IMLLogEntry implements the class HP_CommonLogEntry to model logs records within the IML log.
SMX_IMLUseOfLog 17-2-5 SMX_IMLUseOfLog implements theclass HP_UseOfLog and associates the instance of SMX_ComputerSystem with the instance of SMX_IMLRecordLog. The table below lists the properties implemented. Table 17-6 Class: SMX_IMLUseOfLog Property name Property implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent ref: SMX_IMLRecordLog Dependent ref: SMX_ComputerSystem Supported indications 17-3 There are no indications specific to the profile registration implementation.
Need help?
Do you have a question about the ProLiant BL280c - G6 Server and is the answer not in the manual?
Questions and answers