E-mail Alerts
AlertMail, if enabled, will send out alerts by e-mail for the following events:
●
Enclosure boot message
●
IA reboot message
●
Fan status change
●
Fan inserted
●
Fan removed
●
Enclosure thermal status change
●
Power supply status change
●
Power supply inserted
●
Power supply removed
●
Power subsystem redundancy change
●
Blade inserted
●
Blade removed
●
Blade status change
●
Blade thermal change
●
Blade fault
●
Blade diagnostic string (BC2x00 only) (See
diagnostic strings.)
NOTE:
If the enclosure has a switch installed, it can take up to 60 seconds before the system will send
out an AlertMail after a system boot up. Events generated within this period of time will be sent out when
the switch has come online.
All e-mails have the following header:
Subject: HP AlertMail-SEQ: <SEVERITY> SUBJECT
Date: Date in standard format
From: Enclosure ENCLOSURE-NAME <enclosure-name@domain>
To: RECEIVER MAILBOX
Where SEVERITY is one of the following (from highest to lowest):
●
# CRITICAL
●
# WARNING
●
# NOTICE
●
# INFO
Example e-mail:
ENWW
Error Messages on page 122
for a list of blade specific
Setting Up AlertMail