Xerox 6030 User Manual page 122

Wide format printer with scan system
Hide thumbs Also See for 6030:
Table of Contents

Advertisement

RESET NVR DEFAULTS
SCANNER RELIABILITY
METER
120 Main Menu
The RESET NVR DEFAULTS option is for use by the Customer Service
Engineer only and requires the entry of the diagnostic password. It
allows the Customer Service Engineer to reset the NVR values to the
factory default values.
If you select this option, the RESET NVR DEFAULTS screen is
displayed. You cannot perform any functions in this screen. Press the
Exit key to return to the SCANNER DIAGNOSTICS menu screen.
Below is an illustration of the RESET NVR DEFAULTS screen.
RESET NVR DEFAULTS
WARNING: THIS FUNCTION
DESTROYS NVR CONTENTS
Select the SCANNER RELIABILITY METER option to view the current
value of the usage meter maintained by the SCAN SYSTEM. The meter
counts and displays the number of linear feet since the Scanner Fault
Log was last cleared. The number of linear feet between fault
occurrences is an indication of the reliability of the SCAN SYSTEM.
To run the SCANNER RELIABILITY METER diagnostic:
1. Press the Menu key. The MAIN MENU screen is displayed.
2. Press the Next key until DIAGNOSTICS is highlighted.
3. Press the Enter key to select DIAGNOSTICS. The
DIAGNOSTICS menu screen is displayed.
4. Press the Next key until SCANNER DIAGNOSTICS is displayed.
5. Press the Enter key to select SCANNER DIAGNOSTICS. The
SCANNER DIAGNOSTICS menu screen is displayed.
6. Press the Next key until SCANNER RELIABILITY METER is
highlighted.
7. Press the Enter key to select SCANNER RELIABILITY METER.
The SCANNER RELIABILITY METER screen is displayed.
The SCAN SYSTEM usage meter is intended for gathering data about
the reliability of the scanning mechanism. This meter measures linear
usage only. Units are displayed as either feet or meters depending on
the display units selected for the machine. Refer to "Localization" in the
"Main Menu" section for complete information about setting the display
units.
Below is an example of the SCANNER RELIABILITY METER screen. In
the example, the units are displayed as feet.
EXECUTE: