Migration Procedure for the MDS 9509 Director and MDS 9506 Director

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
switch# show hardware fabric-mode
Fabric mode supports Gen3 and above linecards.
switch#
Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric
Step 9
Manager Configuration Guide for information on how to configure the MDS 9000 48-port or 24-port
8-Gbps Fibre Channel modules.
Migration Procedure for the MDS 9509 Director and MDS 9506
Director
Do not upgrade to NX-OS 4.1(1b) if a Supervisor-1 module is installed.
Note
To use any Generation 3 8-Gbps module in an MDS 9509 Director or MDS 9506 Director, follow these
steps:
Log in to the switch.
Step 1
Verify that the switch is running Cisco NX-OS 4.1(1b) by entering the show version command.
Step 2
If the switch has NX-OS 4.x or higher installed, then Supervisor-2 module is already installed on the
switch. Skip to step 7 to install any Generation 3 8-Gbps module.
Enter the show module command to determine which supervisor module is in active mode and which is
Step 3
in standby module. Supervisor modules are installed in slot 5 and slot 6 on the MDS 9509 Director and
MDS 9506 Director.
The following example shows the output of the show module command:
switch# show module
Mod
---
4
5
6
Mod
---
4
5
6
Mod
---
4
5
6
If the switch has Supervisor-1 modules installed, remove the modules according to the instructions in
Step 4
the
installed, then skip to Step 6.
Cisco MDS 9500 Series Hardware Installation Guide
A-12
Ports
Module-Type
-----
-------------------------------- ------------------ ------------
22
4x1GE IPS, 18x1/2/4Gbps FC Modul DS-X9304-18K9
0
Supervisor/Fabric-1
0
Supervisor/Fabric-1
Sw
Hw
--------------
------
4.1(0.182)
0.304
4.1(0.182)
4.0
4.1(0.182)
0.0
MAC-Address(es)
--------------------------------------
00-19-56-be-65-d0 to 00-19-56-be-65-d8
00-0c-30-0d-2b-b8 to 00-0c-30-0d-2b-bc
00-05-30-00-52-f2 to 00-05-30-00-52-f6
"Removing Supervisor Modules" section on page
Appendix A
Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules
Model
DS-X9530-SF1-K9
DS-X9530-SF1-K9
World-Wide-Name(s) (WWN)
--------------------------------------------------
20:c1:00:05:30:00:a7:9e to 20:d2:00:05:30:00:a7:9e
--
--
Serial-Num
----------
JAB1107027K
JAB074004VE
NA
2-39. If the switch has Supervisor-2 modules
Status
ok
active *
ha-standby
OL-17467-02