Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual page 117

Cisco mds 9500 series hardware installation guide (ol-17467-02, october 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco MDS 9500 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
To power up the switch and verify hardware operation, follow these steps:
Verify that the faceplates of all modules are flush with the front of the chassis, and the ejector levers are
Step 1
fully closed and approximately parallel to the faceplate of the module.
Verify that any empty module slots have filler panels installed.
Step 2
Verify that both power supplies and the fan module are installed.
Step 3
If any optional CompactFlash cards are installed, verify that the ejector button is popped out.
Step 4
Check the captive screws of the power supplies, fan module, and all supervisor, switching, or services
Step 5
modules, and tighten any loose captive screws.
Ensure that the switch is adequately grounded as described in the
Step 6
page
voltages. See
Power on the switch by turning the power switches on the power supplies or PEMs to the on (|) position
Step 7
or restoring power to the DC circuit, as required. The switch boots automatically.
Listen for the fans; they should begin operating as soon as the switch is powered on.
Step 8
Caution
After the switch has finished booting, verify that the LED behavior is as follows:
Step 9
If any LEDs other than the Fibre Channel port LEDs remain orange or red after the initial boot processes
are complete, see
If a component is not operating correctly, try removing and reinstalling it. If it still does not operate
Step 10
correctly, contact your customer service representative for a replacement.
OL-17467-02
2-17, and that the power cables are connected to outlets that have the required AC or DC power
Appendix D, "Technical Specifications,"
Do not operate the switch without a functioning fan module except during the brief fan module
replacement procedure. The Cisco MDS 9000 Family switches can operate for only a few
minutes without a functioning fan module before they begin to overheat.
Fan module: Status LED is green.
Power supplies:
Input OK LED is green.
Fan OK LED is green.
Output Fail LED is off.
Supervisor, switching, or services modules:
The System LED on the supervisor module is green, indicating that all chassis environmental
monitors are reporting that the system is operational. If this LED is orange or red, then one or
more environmental monitor is reporting a problem.
The Status LED on the switching or services modules flashes orange once, remains orange
during diagnostic boot tests, then turns green when the module is operational (online). If the
system software cannot start up, this LED remains orange or turns red.
The LEDs for the Fibre Channel ports remain orange until the ports are enabled, and the
Note
LED for the MGMT 10/100 Ethernet port remains off until the port is connected.
Appendix D, "Technical Specifications."
"System Grounding" section on
for the required voltages.
Cisco MDS 9500 Series Hardware Installation Guide
Starting Up the Switch
2-37