Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual page 109

Cisco mds 9500 series hardware installation guide (ol-17467-02, october 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco MDS 9500 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Providing Power to an AC Power Supply for the Cisco MDS 9513 Director
To provide power to an AC power supply in a Cisco MDS 9513 Director, follow these steps:
Step 1
Plug the power cable into the power supply, and tighten the screw on the cable retention device to ensure
that the cable cannot be pulled out. Each power supply has two AC power connections (as shown in
Figure
Figure 2-15
2
1
Connect the other end of the power cable to an AC power source.
Step 2
Step 3
Turn the power switch to the on (|) position on the power supply.
Step 4
Verify power supply operation by checking that the power supply LEDs are in the following states:
See
OL-17467-02
2-15).
Cable Retention on the Power Supply
2
Power switch
INPUT OK LEDs are green.
FAN OK LEDs are green.
OUTPUT FAIL LED is off.
Table 1-2 on page 1-11
for power supply LED details.
1
2
Cable retention
Cisco MDS 9500 Series Hardware Installation Guide
Starting Up the Switch
2-29

Advertisement

Table of Contents
loading