15
6.
Click OK.
Figure 15-6 Edit IP Interface Dialog Box
7.
Enter the subnet mask.
8.
Enter the MTU size or accept the default MTU size and click OK.
Optional: To configure the IP route
1.
Launch the iSCSI Target Gateway Admin module as described on
2.
Select the iSCSI Port tab.
3.
From the left pane, select the GbE port that will be used.
4.
Select the IP Route tab.
5.
Click Add.
Figure 15-7 Add IP Route Dialog Box
6.
Enter the IP address, subnet mask, and gateway IP address, and the metric.
7.
Enter the MTU size or accept the default MTU size and click Add.
To edit the IP route
1.
Launch the iSCSI Target Gateway Admin module as described on
2.
Select the iSCSI Port tab.
15-10
Note
To change the IP address, delete the current IP address and re-create it. You will not be
allowed to create an additional IP address for this interface, as there can be only one IP
address per interface.