Configuring Virtual Ports - Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Administrator's Manual

Brocade web tools administrator's guide (53-0000194-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

7
4.
Select a policy type from the drop down menu.
Figure 7-2
5.
Choose a policy number.
6.
Select an Encryption Algorithm.
7.
Select an Authentication Algorithm.
8.
(IKE only) Select a Perfect Forward Secrecy.
9.
(IKE only) Select a Diffie-Hellman Group.
10. Enter a value for the Security Association Lifetime in number of seconds.

Configuring Virtual Ports

Each GbE port support up to eight virtual ports. To enable FCIP on these ports, you must configure
them as either VE_Port-to-VE_Port or VE_Port-to-VEX_Port, depending on whether you want to
merge the connected fabrics. Two fabrics connected with VE_Ports will merge. Two fabrics connected
with a VE_Port on one end and a VEX_Port on the other end will not merge. (See the Fabric OS
Administrator's Guide for more information on Fiber Channel routing.)
By default, all tunnels are created as VE_Port-to-VE_Port. If you do not want to merge the fabrics, you
must explicitly configure the port at one end of the tunnel to be a VEX_Port before you configure the
tunnel.
See
"Configuring FCIP Ports"
configure and enable the ports on both the local and remote switches to utilize an FCIP ISL/IFL.
7-8
Create an IKE/IPSec Policy
on page 5-6 for instructions on configuring the virtual ports. You must
Web Tools Administrator's Guide