Hyperterminal Window - HP 316095-B21 - StorageWorks Edge Switch 2/24 Installation Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 installation guide
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

7. Configure the Port Settings parameters as follows:
8. At the > prompt, type the user-level password (the default is password) and
Figure 8: HyperTerminal window
9. At the C> prompt, type ipconfig and press Enter. The HyperTerminal
Edge Switch 2/24 Installation Guide
— Bits per second — 57600
— Data bits — 8
— Parity — None
— Stop bits — 1
— Flow control — Hardware
When the parameters are set, click OK. The HyperTerminal window
displays.
press Enter. The password is case sensitive. The HyperTerminal window
displays with a C> prompt at the top of the window
window displays with configuration information listed as follows:
— MAC Address
— IP Address (default is 10.1.1.10, factory preset is 10.1.1.10)
— Subnet Mask (default is 255.0.0.0).
— Gateway Address (default is 0.0.0.0)
Only the IP Address, Subnet Mask, and Gateway Address fields are
configurable.