Suppress Rscns On Zone Set Activations; Configure Fabric Operating Parameters - HP 316095-B21 - StorageWorks Edge Switch 2/24 Installation Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 installation guide
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Installing and Configuring the Edge Switch 2/24
optic cable being disconnected from a port. Consult with your HBA and storage
device vendor to determine if enabling Domain RSCNs will cause problems with
your HBA or storage products. Note that this option is required if Enterprise
Fabric Mode (optional SANtegrity binding feature) is enabled.

Suppress RSCNs on zone set activations

Fabric format domain register for state change notifications (RSCNs) are sent to
ports on the switch following any change to the fabric's active zone set. These
changes include activating and deactivating the zone set, or enabling and disabling
the default zone. When the Suppress RSCNs on Zone Set Activations check box
is selected, fabric format RSCNs are not sent for zone changes to the attached
devices on the switch. Click the check box to remove or add a checkmark.
This option is enabled (check box not selected) by default. In most cases this
option should be enabled so that attached devices can receive notification of
zoning changes in the fabric. However, some HBAs may log out, then log back
into the fabric when they receive an RSCN, thereby disrupting Fibre Channel
traffic. Consult with your HBA and storage device vendor to determine if
disabling this option (and thereby enabling RSCN transmission) will cause
problems with your HBA or storage products.

Configure Fabric Operating Parameters

Use procedures in this section to set parameters on the switch for fabric operation
through the Configure Fabric Parameters dialog box. These operating
parameters are stored in NV-RAM on the switch.
1. The switch must be offline to change parameters in this dialog box. Ensure the
2. Choose Configure > Operating Parameters > Fabric Parameters from the
58
switch is set offline. For instructions, see
Caution:
Setting the switch offline terminates all Fibre Channel connections.
Product Manager window. The Configure Fabric Parameters dialog box
displays
(Figure
16).
"Set the Switch
Offline" on page 53.
Edge Switch 2/24 Installation Guide

Advertisement

Table of Contents
loading

Table of Contents