Download A Firmware Version To A Switch - HP 316095-B21 - StorageWorks Edge Switch 2/24 Installation Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 installation guide
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Download a Firmware Version to a Switch

This procedure downloads a selected firmware version from the HAFM server
library to a Edge Switch managed by the open instance of the Product Manager
application. The procedure applies to a Edge Switch with two (redundant) CTP2
cards. The process occurs concurrently without taking the Edge Switch offline or
disrupting operation. The new firmware version takes effect when control is
passed from the active to the backup CTP2 card. Although Edge Switch operation
is not affected, name server, alias server, and login server functions are
momentarily unavailable during CTP2 card switchover. Although traffic is not
disrupted, the green port LEDs will flicker or blink during the IPL portion of this
operation as control is passed to the other CTP2 card.
Note:
release notes that accompany the firmware version. This information supplements
information provided in this general procedure.
Use these steps to download a firmware version to a Edge Switch:
1. At the HAFM server, open the HAFM application. The Products View page
2. Before downloading firmware version XX.YY.ZZ to a Edge Switch, ensure the
3. Double-click the icon representing the Edge Switch to which the firmware
4. As a precaution to preserve Edge Switch configuration information, complete
Edge Switch 2/24 Installation Guide
When downloading a firmware version, follow procedural information in the
displays.
required, compatible version of the HAFM application is running on the
HAFM server. Refer to the release notes that shipped with HAFM.
a. Choose Help > About. The About dialog box displays and lists the
HAFM application version. Click OK to close the dialog box.
b. If required, install the correct version of the HAFM application.
version will be downloaded. The Hardware View page for the selected Edge
Switch displays.
the data collection procedure as follows:
a. At the HAFM server, open the HAFM application. The Products View
page displays.
b. Double-click the icon representing the Edge Switch for which the
configuration file will be backed up. The Hardware View page for the
selected Edge Switch displays.
Manage Firmware Versions
107

Advertisement

Table of Contents
loading

Table of Contents