Error Messages
Message
Error 141: Invalid
Enterprise Fabric Mode
Error 142: Invalid
Domain RSCN State
Error 143: Domain
RSCNs Must Be
Enabled When
Enterprise Fabric Mode
Active
Error 144: The
SANtegrity Feature Has
Not Been Installed
Error 146: Fabric
Binding May Not Be
Deactivated While
Enterprise Fabric Mode
Active
Error 148: Not Allowed
While Switch Offline
A–14
Description
The request cannot be
completed because an
invalid enterprise fabric
mode has been submitted.
The request cannot be
completed because an
invalid domain RSCN state
has been submitted.
The user attempted to
disable domain RSCN's
while enterprise fabric mode
was active.
The user attempted to
activate a change to the
fabric security configuration
without first installing the
SANtegrity feature key.
The user attempted to
deactivate fabric binding
while enterprise fabric mode
was active.
The switch must be online
to complete this request.
Action
The enterprise fabric
mode must be set to
either activate or
deactivate.
The domain RSCN state
must be set to either
enable or disable.
Domain RSCN's must
remain enabled while the
enterprise fabric mode is
active. If enterprise fabric
mode is set to inactive,
the domain RSCN state
may be changed. It
should be noted,
however, that this can be
disruptive to the fabric.
If this key has not been
installed, contact your
sales representative.
Fabric binding must be
active while operating in
enterprise fabric mode.
The fabric binding state
may be changed if
enterprise fabric mode is
deactivated. It should be
noted, however, that this
can be disruptive to the
fabric.
Change the state of the
switch to ONLINE and
re-submit the request.