Error Messages
Message
Error 79: FRU Failed
Error 81: Default Zone
Enabled
Error 82: Invalid Interop
Mode
Error 83: Not Allowed in
Open Fabric Mode
Error 88: Invalid
Feature Key Length
Error 89: Not Allowed in
S/390 Mode Without
the SANtegrity Feature
Error 90: Invalid Port
Type
A–10
Description
The specified FRU has
failed.
The request cannot be
completed because the
default zone is enabled
The value entered for the
interoperability mode is not
valid.
This request cannot be
completed while this switch
is operating in Open Fabric
1.0 mode.
The feature key installed is
longer than the maximum
length allowed.
Cannot configure port types
in S/390 mode without
installing SANtegrity.
The port type configured is
invalid.
Action
Consult the
installation/service
manual for appropriate
action.
Disable the default zone
and re-submit the
command.
The interoperability
mode for the Director or
Switch must be mcdata
(Homogenous Fabric) or
open (Open Fabric 1.0).
Make the appropriate
changes and re-submit
the command.
Configure the interop
mode to Homogenous
Fabric mode.
Be sure that the key has
been entered correctly
and re-submit. Contact
your sales representative
with any further
problems.
This command is only
supported when the
switch is in Open
Systems mode or in
S/390 with SANtegrity.
A port may be configured
to be an eport, gport, or
fport. Be sure the port is
configured appropriately
and re-submit the
command.
embedded web server user guide