6.1.6
Thermal Metrology
The maximum TTV case temperatures (T
appropriate TTV thermal profile earlier in this chapter. The TTV T
geometric top center of the TTV integrated heat spreader (IHS).
the location where T
for drawing showing the thermocouple attach to the TTV package.
Figure 6-5.
TTV Case Temperature (T
Note:
The following supplier can machine the groove and attach a thermocouple to the IHS.
The supplier is listed below as a convenience to Intel's general customers and the list
may be subject to change without notice. THERM-X OF CALIFORNIA Inc, 3200
Investment Blvd, Hayward, Ca 94545. Ernesto B Valencia +1-510-441-7566 Ext. 242
ernestov@therm-x.com. The vendor part number is XTMS1565.
52
temperature measurements should be made. See
CASE
) Measurement Location
CASE
Measure T
at
CASE
the geometric
center of the
package
) can be derived from the data in the
CASE-MAX
CASE
37.5
Thermal/Mechanical Specifications and Design Guidelines
Thermal Specifications
is measured at the
Figure 6-5
illustrates
Figure B-12