Intel® Server Chassis SC1400UP / Intel® Server Platform SR1425BK1-E
required, it shall be placed in such a manner that when the power supply is extracted from the
system, the label shall be visible before the operator has a chance to touch the hot surface of
the power supply.

7.19.6 Date Coded Serial Numbers

Power supply shall be marked with a date-coded number for traceability purposes and to
comply with CSA 950 marking requirements

7.19.7 Power Input Electrical Ratings

Power supply shall be tested to allow Nominal AC input operating voltages (100-127 VAC and
200-240 VAC) and current rating. 127V is required for countries such as Mexico
The earth safety conductor shall be color-coded green/yellow and suitable sized for the max
current of the power supply.

7.19.8 Maximum Allowable Temperatures on Inlet Receptacles

The inlet receptacle shall be suitably rated for the maximum operating temperature to the power
supply, when installed in a rack environment

7.19.9 Maximum Allowable Temperatures on Power Cords

The exhaust air of the power supply shall not impose temperatures that will exceed the
maximum allowable temperature of the power cord.