Intel® Server Chassis SC1400UP / Intel® Server Platform SR1425BK1-E
field strength will be determined by the end system vendor during system level testing in the end
use chassis.
7.4
Voltage Fluctuations and Flicker
The power supply shall meet the specified limits of EN61000-3-3, for voltage fluctuations and
flicker for equipment < 16 amps connected to low voltage distribution systems.
7.5
Reliability / Warranty / Service
7.6
Component De-rating
The following component de-rating guidelines shall be followed:
•
Semiconductor junction temperatures shall not exceed 110
Any exceptions are subject to final approval.
•
Transformer temperature shall not exceed 110
exceptions are subject to final approval.
•
Inductor case temperature shall not exceed 85% of rated temperature in
•
Capacitor case temperature shall not exceed 85% of rated temperature in
•
Resistor wattage de-rating shall be > 30%.
•
Component voltage and current de-rating shall be > 15% at operating temperature.
During abnormal conditions ( such as a short circuit and the like) no de-rating is allowed
as long as each component max rating is not exceeded. Any exceptions are subject to
final approval.
7.7
Component Life requirement
All components life expectancy requirement is min 3 years, calculated for: 75% of max
continues load @ 45
7.8
Mean Time Between Failures (MTBF)
The power supply shall have a minimum MTBF at continuous operation of
a. 100,000 hours at 80% load and 45°C, as calculated by Bellcore RPP, or
b. 250,000 hours demonstrated at 75% load and 45°C.
7.9
Warranty Period
Three (3) years.
7.10 Serviceability
No troubleshooting by maintenance personnel is to be performed. Only unit replacement will be
done in the field.
7.11 Power Supply Returned for Repair
Power supplies returned to the vendor for repair, are returned for full credit.
Power supplies returned from vendor repair will be accepted by Intel only after the vendor has
performed an additional burn-in of 4 hours min. at 45°C ± 5°C at maximum load and has re-
tested the power supply following the burn-in.
The vendor shall supply failure analysis, and final test results on all repaired units reshipped to
Intel.
Revision 1.0
°
C ambient temperature and @ 100VAC line voltage.
°
C with an ambient of 45
°
C with an ambient of 45
°
C.
°
C. Any
°
C.
°
C.
- 69 -
Need help?
Do you have a question about the SR1425BK1 - Entry Server Platform and is the answer not in the manual?
Questions and answers