Fujitsu 6240 - fi - Document Scanner Operator's Manual page 183

Image scanner
Hide thumbs Also See for 6240 - fi - Document Scanner:
Table of Contents

Advertisement

Chapter 9 Operational Settings
When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to equal the document length or longer.
If you set a value larger than the document length for
the start position, selecting [Disable] detects the whole
length of the document and selecting [Enable] disables
the multifeed detection.
To detect multifeeds, the detection range must be at
least 5 mm in length.
Configure the setting so that the value of the end
position minus the start position is 6 mm or more.
You can also set the start and the end positions by the
following methods:
- Draw an area with the mouse on the displayed
image.
- Drag the handles for [Start] and [End] positions on
the displayed image.
Example 1:
Position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
35
Multifeeds are detected for the area in light blue.
50
200
Unit: mm
TOP
Contents
Index
Introduction
Scanner
Overview
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Replacing the
Consumables
Troubleshooting
Operational
Settings
Appendix
Glossary
183

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa03630-b055Fi-6130zFi-6230zFi-6140zFi-6240z

Table of Contents