Novell ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009 Installation Manual page 89

Hide thumbs Also See for ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009:
Table of Contents

Advertisement

3 Select Remote Execute Policy, then click Next to display the Policy Name page.
4 Specify a name for the policy, then click Next to display the Remote Execute Policy page.
5 From the Script to run drop-down list, choose Define your own script.
6 Paste the contents of the
script file from the mount point
The Policy script performs the following tasks:
Subscribes to the catalog containing the upgrade bundle.
Installs the upgrade bundle on the managed device.
7 Edit the script so that
Upgrade Bundles" on page 88
catalog
(Step 7 on page
8 Click Next to display the Summary page, then click Next to display the Policy Assignments
page.
9 Click Add to display the Select Assignments dialog box, browse to and select the devices to
which you want to assign the Remote Execute policy, then click OK.
10 Click Next to display the Policy Schedule page.
11 In the Schedule Type drop-down list, select Date Specific, specify a start date and time to apply
the policy, then click Next to display the Policy Groups page.
NOTE: If you want to verify the upgrade immediately, set the start date to today and the start
time to 12 a.m. The Remote Execute policy is executed at the next scheduled refresh for the
devices. Alternately, you can manually refresh the devices.
12 Click Next to display the Finish page, then click Finish.
The Remote Execute policy is enforced as scheduled, after the managed devices' next
scheduled refresh. If the time you specified in
the policy is enforced on the next refresh.
IMPORTANT: It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
command or refer to
rug ping
zmd is 7.2.0. If you perform the
message. You can recover by stopping and restarting zmd. The
contain the
"Starting ZENworks Management Daemon..."
NOTE: Bundle and Package history is not migrated.
Upgrading SLES 10 or SLED 10 Managed Devices by Using an Upgrade Bundle
Perform the following steps on the SLES 10 or SLED 10 managed device:
1 Execute the
/usr/bin/rug sub catalog_name
catalog assigned to the managed device.
script file into the Script content box. You can access the
policy.sh
directory.
/data
is the catalog you created in
catalog_name
and
is the bundle that you specified while creating the
bundle
88).
Step 11
. The upgrade was successful if the version of
upgrade.log
command prematurely, you receive an exception
rug ping
"Creating Catalogs for
occurs before the next scheduled refresh,
/tmp/zmd/upgrade.log
message in the last line.
command, where catalog_name is the
Upgrading to ZENworks 7.2 Linux Management
rug ref
must
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks linux management 7.2 ir2

Table of Contents