Novell ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009 Installation Manual page 101

Hide thumbs Also See for ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009:
Table of Contents

Advertisement

The Remote Execute policy is enforced as scheduled, after the managed devices' next
scheduled refresh. If the time you specified in
the policy is enforced on the next refresh.
IMPORTANT: It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
command or refer to
rug ping
zmd is 7.2.0. If you perform the
message. You can recover by stopping and restarting zmd. The
contain the
"Starting ZENworks Management Daemon..."
NOTE: Bundle and Package history is not migrated.
Upgrading SLES 10 or SLED 10 Managed Devices by Using an Upgrade Bundle
Perform the following steps on the SLES 10 or SLED 10 managed device:
1 Execute the
/usr/bin/rug sub catalog_name
catalog assigned to the managed device.
2 Execute the
/usr/bin/rug bin -y upgrade_bundle_name
upgrade_bundle_name is the upgrade bundle in the catalog assigned to the managed device.
IMPORTANT: It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
command or refer to upgrade.log. The upgrade was successful if the version of zmd
rug ping
is 7.2.0. If you perform the
message. You can recover by stopping and restarting zmd. The
contain the
"Starting ZENworks Management Daemon..."
3 If the device does not have the X Window System installed:
3a In ZENworks Control Center, click the upgrade bundle.
3b Click the Details tab.
3c In the Packages panel, select the following packages:
novell-zenworks-x11vnc-0.6.1-2
novell-zenworks-zmd-gconfpolicyenforcers-7.2.1-0
novell-zenworks-tightvnc-1.2.9-6, zen-updater-7.2.1-0.1
3d Click Action > Set Freshen.
Step 11
. The upgrade was successful if the version of
upgrade.log
command prematurely, you receive an exception
rug ping
command, where catalog_name is the
command prematurely, you receive an exception
rug ping
Upgrading to ZENworks 7.2 Linux Management with IR1/IR1a 101
occurs before the next scheduled refresh,
/tmp/zmd/upgrade.log
message in the last line.
command, where
/tmp/zmd/upgrade.log
message in the last line.
rug ref
must
rug ref
must

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks linux management 7.2 ir2

Table of Contents