Connecting Siren Drivers, Self-Contained Sirens, And Bells - GE 60-806-95R-16Z - Security Concord Express System Control Panel Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

Note
Some versions of this siren
may have two wires of each
color. Only one black wire
and one yellow wire are
needed for panel connec-
tions.
Note
For UL Listed systems,
Siren Verify must be on and
the 2k end-of-line resistor
installed.
Note
Piezo siren connections to
terminal 8 require a 2k
end-of-line resistor that can
be located at the panel since
it does not supervise the cir-
cuit.
Note
If using an external power
supply instead of panel ter-
minal 4, the supply voltage
must be limited to 9.5 VDC
maximum and the negative
side of the power supply
must be connected to panel
ground (terminal 3).
Note
If the backup battery is not
connected, or if the configu-
ration of panel terminal 7 is
programmed to anything
other than the default
(00410), then the combined
currents of terminal 7 (OUT
1/+12) and terminal 4 (+12V)
must not exceed 750 mA.
13
For UL Listed installations, you can connect only one 15-Watt, Dual-Tone Siren to panel termi-
nals 3 and 7 as shown in Figure 12. For all other installations, connect up to two sirens. This siren
does not require an end-of-line resistor.
Hardwire Siren (13-046)
Connect one or two sirens to the panel with supervision as shown in Figure 13. If Siren Verify is
turned off (see the section "Programming the Panel"), the 2k end-of-line resistor is not required.
Black
Red
2k Ohm EOL Resistor 49-454
(Locate at Siren)
Interior Piezo Siren (30-006)
Panel terminal 8 (OUT2/OC) is an open-collector (switched path-to-ground), programmable out-
put that can handle up to a 200 mA current.
The default setting (01710) activates the output for status and alarm tones, which allows for a
piezo siren connection without changing the output configuration number.
Connect the piezo siren to the panel terminals with a 2k end-of-line resistor as shown in
Figure 14.
Panel
Terminals
Black
2k Ohm
Resistor
49-454
Red
Figure 14. Connecting an Interior Piezo Siren

Connecting Siren Drivers, Self-Contained Sirens, and Bells

Power for a siren driver, self-contained siren, or bell can be connected to panel terminals 7
(OUT1/+12V) and 3 (GND).
Panel terminal 7 (OUT1/+12V) is a +12-volt programmable output. At the default configuration
setting (00410), this output can provide up to 1.25 A during an alarm (650 mA for
UL Listed systems) if the backup battery is connected.
The default configuration setting (00410) activates the output during any audible alarm.
The following siren drivers, self-contained sirens, and bells have been tested and found compati-
ble for use with the panel:
Moose Models MPI-11 (use only 8-ohm speaker loads), MP-47, MP-47B
Altronix Model ALSD2 (4- or 8-ohm speaker loads)
ATW Models DT-24, DS508 (both self-contained)
Wheelock MB-G6-12 Six-inch, 12V Bell
Refer to the manufacturer's documentation for installation details.
Panel
Terminals
Figure 13. Connecting Hardwire Siren 13-046
Panel
Terminals
Black
Red
2k Ohm EOL Resistor 49-454
(Locate at Last Siren)