Quick Exit (0012)
This setting determines whether or not users can open and close a standard
entry or exit door without causing an alarm (while the system is armed). This
feature would be useful if the user wanted to go out to get the morning paper
while the system was armed. This feature also allows the user to leave the
armed premises without having to disarm and rearm the system.
Note
For UL Listed systems, Quick Exit must be turned off.
When this feature is on, pressing D on a touchpad (while the system is
armed) starts a 2-minute timer that allows one standard entry or exit door
(sensor groups 10 and 19 only) to be activated once (opened, then
closed).When this feature is turned off, the system must be disarmed before
opening any protected door.
Exit Extension (0013)
This setting determines whether or not the user can reenter and exit again
through an entry or exit delay door (without disarming and rearming the sys-
tem). This helps prevent exit faults and false alarms by allowing users to
reenter the armed premises for a forgotten item.
When Exit Extension is on, the panel restarts the exit delay timer if the user
reenters the premises through a designated delay door before the exit delay
time expires.
When Exit Extension is off, the exit delay timer does not restart if the user
reenters the premises. This forces the user to disarm the system to avoid set-
ting off an alarm.
Auto Stay Arming (0014)
This setting determines whether or not the system automatically arms to
STAY (level 2) if the user arms the system to AWAY (level 3) without exit-
ing the premises. This can help prevent accidental alarms by deactivating
interior motion sensors during occupied arming periods.
Note
Arming the system to AWAY with No Delay overrides the Auto Stay Arming fea-
ture.
With the feature turned on, the user arms the system to AWAY. Touchpads
(and other status sounders) emit one exit delay beep every four seconds, then
one every second during the last 10 seconds. If the exit delay time expires
with no standard delay sensor activation, the system automatically arms to
STAY.
Programming the Panel
Security-Partition 1 (Default = on)
¾
To turn Quick Exit off or on:
1. With the display showing
(current setting), press 1 (off) or 2
ON
(on). The display flashes the entered setting.
2. Press ƒ and the display shows the new set-
ting.
Security-Partition 1 (Default = on)
¾
To turn Exit Extension off or on:
1. With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2. Press ƒ and the display shows the new set-
ting.
Security-Partition 1 (Default = on)
¾
To turn Auto Stay Arming off or on:
1. With the display showing
(current setting), press 1 (off)
ING OFF/ON
or 2 (on). The display flashes the entered
setting.
2. Press ƒ and the display shows the new set-
ting.
QUICK EXIT OFF/
EXIT EXTENSION
AUTO STAY ARM-