Disable Trouble Beeps (0601)
This setting determines whether or not the panel activates trouble beeps when
a wireless device supervisory condition is detected.
Note
For UL Listed systems, this feature must be off.
UL 98 Options (0602)
This setting determines whether or not the panel complies with UL 98 require-
ments (4-hour trouble beep restart, 4-hour backup battery test, 2-hour supervi-
sory time period for sensor group 26—Fire).
Note
For UL Listed systems, this feature must be on.
Siren Verify (0610)
This setting determines whether or not the panel monitors sirens connected to
panel terminal 7 (OUT1/+12V).
When this feature is on, sirens connected to panel terminals 3 (GND) and 7
(OUT1/+12V) require a 2k end-of-line resistor. Refer to "Installing the Sys-
tem—Connecting Sirens" for complete details.
Note
For UL Listed systems, this feature must be on.
Note
If 2-wire smoke detectors
are connected to hardwire
zone input 6, the Two-wire
Smoke setting must be
turned on before entering
the
LEARN SENSORS
menu.
See
ONBOARD OPTIONS—
INPUTS
.
Programming the Panel
The following describes how to program the settings that appear under
PARTITION 1.
Sensors Menu
The
SENSORS
menu gives you access to the following:
—lets you learn hardwire zones and wireless sensors into panel memory and
LEARN SENSORS
assign zones/sensors to specific partitions.
—lets you program sensor text for zone/sensor identification.
SENSOR TEXT
—lets you delete zones/sensors from panel memory.
DELETE SENSORS
—lets you view and/or change sensor/zone group assignment, view sensor
EDIT SENSORS
number and text assignments of learned sensors/zones, identify whether zone is wireless or
hardwire, and indicates sensor/zone/touchpad input N/C or N/O configuration.
The following describes how to program the sensor settings that appear under
Siren Options-Global (Default=off)
¾
To turn Disable Trouble Beeps off or on:
With the display showing
1.
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2. Press ƒ and the display shows the new set-
ting.
Siren Options-Global (Default=off)
¾
To turn UL 98 Options off or on:
1. With the display showing
(current setting), press
OFF/ON
(on). The display flashes the entered setting.
ƒ
2. Press
and the display shows the new set-
ting.
SIREN OPTIONS—
Siren Options-Partition 1 (Default=off)
¾
To turn Siren Verify off or on:
1.
With the display showing
(current setting), press
OFF/ON
2 (on). The display flashes the entered
setting.
ƒ and the display shows the new
Press
2.
setting.
DISABLE TR BEEPS
UL 98 OPTIONS
1
2
(off) or
SIREN VERIFY
1 (off) or
.
LEARN SENSORS
38