No.
Name
08
Special Intrusion
09
Special Intrusion
10
Entry/Exit Delay
11
Entry/Exit Delay
12
Entry/Exit Delay
13
Instant Perimeter
14
Instant Interior
15
Instant Interior
16
Instant Interior
17
Instant Interior
18
Instant Interior
19
Delayed Interior
20
Delayed Interior
21
Local Instant Interior
22
Local Delayed Interior Same as group 21, plus activation initiates a
23
Local Instant Auxiliary 24-hour local alarm zone protecting anything
24
Local Instant Auxiliary 24-hour local alarm zone protecting anything
25
Local Special Chime
26
Fire
27
Output Module
28
Output Module
29
Auxiliary
32
Output Module
34
Gas
35
Local Instant Police
(Day Zone)
Appendix A: System Configuration Worksheets
Table A3: Sensor Group Characteristics (Continued)
Application
Special belongings, such as gun cabinets
and wall safes.
Special belongings, such as gun cabinets
and wall safes.
Entry and exit doors that require a standard
delay time. #
Garage doors and entrances that require an
extended delay time. * #
Driveway gates and entrances that require a
twice extended delay time. * #
Exterior doors and windows. #
Interior doors. #
Interior PIR motion sensors. * #
Interior doors. #
PIR motion sensors. * #
PIR motion sensors subject to false alarms. *
#
Interior doors that initiate a delay before
going into alarm. * #
PIR motion sensors that initiate a delay
before going into alarm. * #
24-hour local alarm zone protecting anything
that opens and closes.
delay before going into alarm.
that opens and closes. ‡
that opens and closes. Sirens shut off at
restoral. *
Notify the user when a door is opened.
Sounds emit from a local annunciator. *
24-hour fire, rate-of-rise heat, and smoke
sensors. §
Hardwire Output Module (HOM) lamp control
or other customer feature. ‡
HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Freeze sensor.
HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Carbon monoxide (CO) Gas Detectors ‡
Local alarm in levels 1 and 2.
Reports to CS in level 3.
Alarm
Delay
Police
Instant
Police
Standard
Police
Standard
Police
Extended
Police
Twice
Extended
Police
Instant
Police
Follower
Police
Follower
Police
Follower
Police
Follower
Police
Follower
Police
Standard
Police
Standard
Police
Instant
Police
Standard
Auxiliary Instant
Auxiliary Instant
Special
Instant
Chime
Fire
Instant
Silent
Instant
Silent
Instant
Auxiliary Instant
Silent
Instant
Auxiliary Instant
Police
Instant
Active
Levels
1, 2, 3
1, 2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
3
3
3
3
3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
(level
3
only)
56

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-80660-806-95rConcord express