Receiver Failure (05011)
When this setting is on, the panel reports a receiver failure if either no wireless
sensor signals have been received for two hours or if signals are being
received constantly (jamming the receiver).
Note
For UL Listed installations that include wireless devices, this feature must be on.
RF Low Bat Rpt (05012)
This setting determines whether the panel reports to the central monitoring
station (or pager) daily or weekly when a wireless device reports a low battery
condition to the panel.
RF Supv Report (05013)
This setting determines whether the panel reports to the central monitoring
station (or pager) daily or weekly when the panel detects a wireless device
supervisory condition.
Swinger Limit (05014)
This setting determines the maximum number of times a sensor or zone can go
into alarm (during a single arming period) before the panel automatically
bypasses that sensor or zone. This feature only applies to sensors in groups 00-
20, 29, or 34.
When set to 1, the panel automatically bypasses a sensor or zone after it
causes an alarm. When set to 2, the panel waits until a sensor or zone has
caused a second alarm (during the same arming period) before bypassing it. At
either setting, the automatic bypass is logged into the event buffer.
A bypassed zone or sensor will be cleared (automatically "unbypassed") if the
system receives no further activations from that sensor or zone over the next
48-50 hours.
Changing the arming level also clears all automatically bypassed sensors and
zones and resets the Swinger Limit count on all sensors and zones.
35
The following describes how to program the settings that appear under
Reporting-Global (Default=off)
¾
To turn Receiver Failure reports off or on:
1. With the display showing
(current setting), press
OFF/ON
(on). The display flashes the entered setting.
ƒ
2. Press
and the display shows the new set-
ting.
Reporting-Global (Default=weekly)
¾
To set RF Low Battery Report to daily or
weekly:
1. With the display showing
(current setting), press
DAILY/WEEKLY
2
(daily) or
(weekly). The display flashes
the entered setting.
ƒ
2. Press
and the display shows the new set-
ting.
Reporting-Global (Default=weekly)
¾
To set RF Supv Report to daily or weekly:
1. With the display showing
(current setting), press
DAILY/WEEKLY
2
(daily) or
(weekly). The display flashes
the entered setting.
ƒ
2. Press
and the display shows the new set-
ting.
Reporting-Global (Default=1)
¾
To set the Swinger Limit:
1. With the display showing
(current setting), press
flashes the entered setting.
ƒ
2. Press
and the display shows the new set-
ting.
REPORTING—PARTITION 1
Programming the Panel
RECEIVER FAILURE
1
2
(off) or
RF LOW BAT RPT
1
RF SUPV REPORT
1
SWINGER LIMIT n
1
2
or