Ul-Canada Listed Systems; Planning The Installation; Standard Panel - GE 60-806-95R-16Z - Security Concord Express System Control Panel Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

Note
For UL 1635 installations,
Entry Delay plus Dialer
Abort Delay must not
exceed 60 seconds.
Note
For 24-hour backup, exter-
nal power drain is limited to
90 mA continuous using a
4.0AH battery.
Planning the
Installation
3
Function
Cancel Report Annunciation
UL 1635 Digital Alarm Communicator System
Same as UL 1023 & 985 plus:
AC FAILURE set to on
PHONE NUMBER must be programmed
HIGH LEVEL REPORTS set to on.
LOW LEVEL REPORTS set to on
PHONE TEST set to on
AUTO PHONE TEST set to on
PHONE TEST FREQ. set to 1
NEXT PHONE TEST set to 1
LOW CPU BATTERY set to on
COMM FAILURE set to on
RF TX TIMEOUT set to 4 hours
Central Station Reporting
The panel has been tested with the following central station receivers using SIA and Contact ID
reporting formats:
ITI CS-5000 Central Station Receiver
Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2

UL-Canada Listed Systems

This section describes the requirements for ULC (UL Canada) Listed systems.
CSA Certified Accessories
The UL-Canada Basic System is nearly the same as the "UL Basic System" described previ-
ously, the only difference being that you must use the ITI 60-679-CN Class II transformer
(Basler part number BE 116250-AAA) to power the panel.
Residential Burglary Alarm System Unit
(CAN/ULC-S309)
Same as "UL Basic System and Household Burglary Alarm System Unit (UL 1023)"
described previously and siren timeout must be set to 5 minutes or more.
Residential Fire Warning System Control Unit (CAN/ULC-S545-M89)
Same as "UL Basic System and Household Fire Warning System (UL 985)" described previ-
ously.
California State Fire Marshall Listed Systems
Same as Household Fire Warning System (UL 985), plus:
SMOKE VERIFY must be set to off
This section describes the system capabilities to help you get familiar with the system. To help
you prepare for system installation, Appendix A provides planning sheets with tables that let you
record the hardware and programming configuration of the system.

Standard Panel

The following describes the basic panel (out-of-box) hardware capabilities.
Power: Input for an AC step-down, plug-in style transformer.
Auxiliary Power Output: Output that supplies up to 750 mA (90 mA for UL Listed systems)
at 12 VDC for bus devices and hardwired detectors, such as touchpads and motion detectors.
Operation
Enabled

Planning the Installation